Hardware Installation

Installation Precautions

To prevent equipment damage or personal injury caused by improper use,
observe the following precautions:

During the installation process, you need to wear anti-static gloves or
anti-static gloves, and power-off the switch.

Please make sure that the input voltage is within the input voltage range
marked on the switch.

The transmission distance has a certain relationship with the connected
wire. It is recommended to use a standard Cat5e/6 network cable.

The equipment must be grounded for lightning protection, otherwise the
protection level of the equipment will be greatly reduced; please use a
wire of No.20 or more to connect the grounding terminal to the ground.

The power line, ground line and signal line are laid out separately and the
distance is not less than 5cm.

[Device installation]

Install rack-mounted equipment

Rack-mounted installation, the installation steps are as follows:

Step 1 Select the installation location of the device and make sure it has
sufficient size.

Step 2 Use 2 screws to install the mounting ear to the position of the
device as shown in the figure below.

Step 3 Put the device on the rack, and use 4 screws to fix the left and
right side brackets to the rack respectively.

Step 4 Check and confirm that the product is securely installed on the
rack, and the installation is complete.

Содержание MISCOM8028GX-4XGF-16GF-8GC

Страница 1: ...trial Ethernet Switch 1PCS Power cord 1PCS AD220 model only User Manual 1PCS Console cable 1PCS This series is L3 aggregation managed rack mount industrial Ethernet switch MISCOM8028GX 4XGF 16GF 8GC p...

Страница 2: ...1 Input V1 AC N Negative DC 3 Grounded 4 Power 2 Input V2 AC L Positive DC 5 Power 2 Input V2 AC N Negative DC Connect to the relay This series of switches supports the relay alarm function and the wi...

Страница 3: ...e power is not connected or the system is not operating normally RUN Flashing The system is operating normally On Off The system is not working properly ALM On Device power failure alarm port offline...

Страница 4: ...on level of the equipment will be greatly reduced please use a wire of No 20 or more to connect the grounding terminal to the ground The power line ground line and signal line are laid out separately...

Страница 5: ...ver through the browser Configure the IP addresses of the computer and the device in the same network segment and ensure that the computer and device can access each other Enter the IP address of the...

Страница 6: ...ered IP protection IP40 Weight About 4 5kg Working environment Working Temp 40 70 Storage Temp 40 85 Humidity 5 95 No condensation Industry Standard EMC IEC61000 4 2 ESD Level 4 IEC61000 4 5 Surge Lev...

Страница 7: ...ct back to Maiwe for repair it is recommended that the customer use the original packaging or the packaging with the same protective effect otherwise the customer shall bear the risks that occur durin...

Отзывы: