Number

Pin definition

1

Alarm relay output normally open

2

Alarm relay output common terminal

3

Alarm relay output normally closed

[Connect the CONSOLE port]

The network management port is an RJ45 port, please use the serial port
cable of our company to connect to the serial port of the PC. The interface
communication standard is 3-wire RS232.
The communication parameters of the serial port are as follows:
Baud rate: 9600, data bit: 8, parity bit: None, Stop bit: 1, flow control: None.

The switch indicator lights description is shown in the table below:

Indicator

lights

Status

Definition

System Status LED

PWR1/PWR2

On

The power is connected and operating normally

Off

The power is not connected or the system is
not operating normally

RUN

Flashing The system is operating normally

On/Off

The system is not working properly

ALM

On

Device power failure alarm, port offline alarm,

network storm alarm

Off

Device no alarm

Fiber Port Status LED

X1-X4

On

The port has established a valid network
connection

Flashing There is network activity on the port

Off

No valid network connection is established on
the port

RJ45 Port Status LED

Each RJ45 port has two indicator lights, the yellow light is the port plastic
rate indicator, the green light is the port connection status indicator.

1000M

(Yellow)

On

1000M working state

Off

10/100M working status

Link/Act

(Green)

On

The port has established a valid network
connection

Flashing There is network activity on the port

Off

No valid network connection is established on
the port

[Installation Size]

Содержание MISCOM8028GX-4XGF-16GF-8GC

Страница 1: ...trial Ethernet Switch 1PCS Power cord 1PCS AD220 model only User Manual 1PCS Console cable 1PCS This series is L3 aggregation managed rack mount industrial Ethernet switch MISCOM8028GX 4XGF 16GF 8GC p...

Страница 2: ...1 Input V1 AC N Negative DC 3 Grounded 4 Power 2 Input V2 AC L Positive DC 5 Power 2 Input V2 AC N Negative DC Connect to the relay This series of switches supports the relay alarm function and the wi...

Страница 3: ...e power is not connected or the system is not operating normally RUN Flashing The system is operating normally On Off The system is not working properly ALM On Device power failure alarm port offline...

Страница 4: ...on level of the equipment will be greatly reduced please use a wire of No 20 or more to connect the grounding terminal to the ground The power line ground line and signal line are laid out separately...

Страница 5: ...ver through the browser Configure the IP addresses of the computer and the device in the same network segment and ensure that the computer and device can access each other Enter the IP address of the...

Страница 6: ...ered IP protection IP40 Weight About 4 5kg Working environment Working Temp 40 70 Storage Temp 40 85 Humidity 5 95 No condensation Industry Standard EMC IEC61000 4 2 ESD Level 4 IEC61000 4 5 Surge Lev...

Страница 7: ...ct back to Maiwe for repair it is recommended that the customer use the original packaging or the packaging with the same protective effect otherwise the customer shall bear the risks that occur durin...

Отзывы: