MIEN5208 Series Managed Industrial Ethernet Switch
- 30 -
benefit of this feature is the ability to remotely reboot the switch, allowing users
to remotely reboot as long as they have remote access to the switch.
The device restore factory configuration:T
his function is used to
restore the switch to the factory settings and automatically restart the switch.
Before the switch restarts successfully, the switch does not work and cannot
forward any packets. This function can be restored to the factory default
configuration value when the user fails to work properly if the wrong
parameters are set. On the right side, there is a “Retain current IP address”
option. When checked, the current IP address will be retained. If it is not
checked, the IP address will also be restored to the factory default address:
192.168.16.253.Click the Start button, the page pops up a prompt box, click
"OK" to jump to the waiting page, after the progress bar in the page is read, the
switch resumes the factory configuration.
Device upgrade:
This function is used to upgrade the software of the
switch. Users can obtain the upgrade program of the switch through email or
our website. Please pay attention to the matching of the model and version of
the switch. Using the unmatched upgrade program may cause permanent
damage to the switch.
Equipment upgrade:
After the user gets the upgrade program, click the
Browse button to select the upgrade program, and then click the Start button.
The page pops up a prompt box. Click “OK” to jump to the Waiting page. After
the progress bar in the page is read, the switch upgrade is completed.
Attention
:
1. Restoring the factory default setting will cause all the settings to be in
the factory state. If you want to keep the IP, please check the “Retain current
IP address” on the right, otherwise the IP address will be restored to the
default configuration of 192.168.16.253;
2. Do not upgrade the device casually. When the device needs to be
upgraded, you must determine whether the upgrade file is correct.
Otherwise, the software of the device may be damaged and the switch may
be faulty.
3. Do not operate the switch during the upgrade process. Do not click
the switch web page. If the upgrade is interrupted due to incorrect operation,
restart the switch and try again.
4. The entire upgrade process does not allow power failure. Power
failure may cause permanent damage to the switch. If the upgrade is
interrupted, please mail the product to the company immediately to seek a
possible solution.