1.
Signals were transmitted by laser through optical fiber. The laser meets the
requirement of class I, no harm with normal operation. Do not look directly into the
fiber port and the end of the optical fiber terminator.
2.
Dust plugs need to be installed when optical connectors and optical modules are
not in use. Dust caps need to be installed when optical fibers are not in use.
3.
The bending radius of optical fiber should be greater than 20 times the diameter of
the optical fiber. In general, the bending radius should be equal to or greater than
40mm.
1.
When using a switch, the voltage can only be input from V1+ and V1-, V1+ connects
to live wire L, and V1- to neutral wire N. Do not connect from V2+, V2-; pay attention
to safety and prevent electric shock.
2.
Power-on operation: First connect the power cord to the power terminal of the
device according to the definition shown in the figure above, and then power on.
3.
Power-off operation: first unplug the power plug, and then remove the power cord.
Warning
Power input
Before connecting the power cord, make sure that the ground is connected. Do
connect the power cord to the power terminal of the device according to the definition.
Notes
MIEN2206-2F
MIEN2208
Switch properties
Bandwidth
1.6G
Cache size
768Kbit
MAC table
2K
Interface
100M fiber port
2*100Base-FX
/
SC/FC/ST connectors are available
100M copper port
4*10 /100Base-TX RJ45 ports
8*10 /100Base-TX RJ45 ports
Full-duplex/half-duplex adaptive, supports MDI/MDI-X adaptive
Power supply
Consumption
2.6W@24V(MAX)
1.8W@24V(MAX)
DC power input
DC9-60V
Supports dual power supply redundancy and reverse connection protection
AC power input
AC85~264V (frequency: 47~63Hz) or DC110~370V
Mechanical
Size
140mm×35mm×100mm
(
L×W×H
)
(not include din-rail)
Installation
35mm standard din-rail
Heat
Aluminum alloy single-rib chassis surface scattered
IP protection
IP40
Weight
About 0.54kg
Working environment
Working Temp.
-40
℃
~+85
℃
Storage Temp.
-40
℃
~+85
℃
Humidity
5%~95%
(
No condensation)
)
Specifications