MAITEC ARMATUREN LuxuryBlack i14 Скачать руководство пользователя страница 2

 

 

 

 

 

 

 

 

 
 

 
 
 

 

 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание LuxuryBlack i14

Страница 1: ...SWIMMING POOL HEAT PUMP User and Service Manual Art Nr 7008470M 7008471M 7008472M 7008475M 7008476M...

Страница 2: ......

Страница 3: ...1 INDEX FOR DIFFERENT LANGUAGES Bedienungsanleitung Deutsch P2 P40 English manual P41 P76 Manuel fran ais P77 Manuale italiano P P Instruction of WIFI connection P P...

Страница 4: ...2 SCHWIMMBAD W RMEPUMPE Benutzer und Wartungshandbuch LUXURYBLACK INVERTER...

Страница 5: ...und der Handhabungssicherheit der betreffenden Typen und Gr e der Ausr stung beinhaltet Aufbewahrung der Aufzeichnungen 1 Die Betreiber von den Ger te die auf Dichtheit berpr ft werden m ssen m ssen...

Страница 6: ...ion des Produkts und sollte allen Anweisungen des Herstellers sowie allen Vorschriften in den Anwendungen folgen Inkorrekte Installation gegen die Anweisungen des Handbuchs macht die Garantie nichtig...

Страница 7: ...8 0 5 8 0 5 8 2 5 8 2 5 8 2 5 C O P in Turbo 4 6 4 6 4 5 4 6 4 5 C O P at 50 capazit t 6 8 6 8 6 7 6 8 6 7 Allgemeine Daten Kompressortyp Wechselrichterkompressor Spannung V 220 240V 50Hz 1PH 380 415V...

Страница 8: ...6 2 Abmessung LuxuryBlack i14 LuxuryBlack i16...

Страница 9: ...7 LuxuryBlack i20...

Страница 10: ...8 LuxuryBlack iV26 LuxuryBlack iV30...

Страница 11: ...rleitung um das Wasser abzulassen Hinweis Heben Sie die W rmepumpe an um die Ablassschraube zu installieren Die W rmepumpe niemals umkippen da dies den Kompressor besch digen k nnte Wasserzulauf und W...

Страница 12: ...Verkabelung der Filtrationspumpe Trockenkontakt 1 ffnen Sie die obere Abdeckung der W rmepumpe 2 Schlie en Sie die Kabel gem Schaltplan an der richtigen Klemme an Anschluss zur Steuerung der Wasserpum...

Страница 13: ...niemals in einem geschlossenen Raum mit begrenztem Luftvolumen wo die von der Einheit ausgesto ene Luft wiederverwendet wird oder nahe an Str uchern die den Lufteinzug blockieren k nnten Solche Positi...

Страница 14: ...ratur im Pool und der Temperatur des das Rohr umgebenden Bodens Dies erh ht die Betriebszeit um 3 bis 5 3 4 Installation des Sperrventils Hinweis Wenn ein automatisches Dosierger t f r den Chlor und S...

Страница 15: ...nbetriebnahme Nachdem alle Verbindungen hergestellt und gepr ft sind f hren Sie die folgenden Schritte durch 1 Schalten Sie die Filterpumpe aus Pr fen Sie ob es ein Leck gibt und stellen Sie sicher da...

Страница 16: ...usfall l st diese Zeitverz gerung aus und verhindern so dass das Ger t nach einem Neustart sofort wieder l uft Zus tzliche Stromunterbrechungen w hrend dieser Verz gerung haben keinen Einfluss auf die...

Страница 17: ...hr H ndler m glicherweise den Anfangswert anpassen Zeitverz gerung Die W rmepumpe verf gt ber eine integrierte Anlaufverz gerung von 3 Minuten um die Schaltung zu sch tzen und berm igen Kontaktverschl...

Страница 18: ...Wassertemperatur direkt einzustellen Dr cken Sie und gleichzeitig um die Wassereintrittstemperatur die Wasseraustrittstemperatur und die eingestellte Temperatur zu berpr fen Beachtung 1 Die Anzeigeta...

Страница 19: ...Heiz K hl Auto Modus W hlen Sie und dr cken Sie zum Aufrufen dr cken Sie und um zwischen Heizen K hlen Automatikmodus zu w hlen und dr cken Sie erneut um das Men zu verlassen Der Standardmodus ist der...

Страница 20: ...chter Testwert d7 Schritt der EEV 0 99 N 5 d8 Kompressorlauffrequenz 0 99 Hz Echter Testwert d9 Kompressorstrom 0 30 A Echter Testwert d10 Aktuelle L ftergeschwindigkeit 0 1200 U min Echter Testwert d...

Страница 21: ...30 Minuten P3 0 T1 28 5 f r eine Dauer von 30 Minuten 1 Dann wechselt sie f r 1 Stunde in den Standby Modus Neustart nur durch manuelles Einschalten m glich 2 Nach 1 Stunde startet die Filtrationspum...

Страница 22: ...t ist Bedingung zum Stoppen der W rmepumpe Timer AUS ist aktiv Vor dem TIMER OFF stoppt die W rmepumpe und die Filtration ist noch aktiviert Wenn der Timer die eingestellte Zeit von TIMER OFF erreicht...

Страница 23: ...n Sie zum Aufrufen und und um Timer ein oder Timer aus zu w hlen Dr cken Sie um Ein Aus auszuw hlen und dr cken Sie oder um die Zeit einzustellen Dr cken Sie um die Einstellung zu speichern Halten Sie...

Страница 24: ...fen 3 Durch das Hochdruckmessger t zur berpr fung des Druckwertes Kein Wasserfluss oder Wasserflussschalteraus fall ON 1 Wasser Flow Schalter ist in schlechter Verbindung 2 Wasserstromschalter ist be...

Страница 25: ...alten und Maschine neu starten 4 ndern eines neuen Controllers Kommunikationsfehler zwischen Hauptplatine und Treiberplatine EE 09 1 Anschluss der Verbindung Draht 2 Der Draht ist besch digt 1 Dr cken...

Страница 26: ...erpr fen Sie ob die Motordrehzahl zu niedrig ist oder der L ftermotor besch digt ist ndern Sie einen anderen 3 Klappen Sie ein anderes L fterblatt 4 berpr fen Sie die Eingangsspannung DC L ftermotorau...

Страница 27: ...Verdrahtung gem Schaltplan 4 Wege Ventilumkehrv ersagen EE 26 1 Four Wege Ventilumkehrversagen 2 Lack K ltemittel keine Erkennung wenn T3 oder T5 St rung 1 Schalten Sie den K hlmodus um das 4 Wege Ven...

Страница 28: ...Sensor Frostschutz im Winter PP 07 Die Umgebungstemperatur oder die Wassereintrittstemperatur ist zu niedrig Normaler Schutz Niedriger Umgebungstemperatur schutz PP 08 1 Geben Sie den Umfang der Nutz...

Страница 29: ...an Zum Beispiel unten Modus Wasseraustritt stemperatur Temperatur einstellen Bedingung Fehlfunktion Heizmodus 36 29 Tout Tset 7 EE04 berhitzungsschutz f r Wassertemperatur T2 K hlmodus 23 30 Tset Tou...

Страница 30: ...st defekt 1 Stellen Sie den Modus richtig ein 2 Ersetzen Sie die defekte LED Kabelsteuerung und berpr fen Sie den Status nachdem Sie in den Betriebsmodus bergegangen sind schlie lich berpr fen Sie die...

Страница 31: ...29 7 Elektronische Verkabelung 5 1 Umrichter Schwimmbad W rmepumpe Schaltplan LuxuryBlack i14 LuxuryBlack i16 LuxuryBlack i20...

Страница 32: ...30 LuxuryBlack iV26 LuxuryBlack iV30 Oberhalb Schaltplan ist nur als Ihre Referenz bitte bieten Sie die Maschine mit den Schaltplan...

Страница 33: ...ren 2 Reinigen Sie ihr Becken und Filtersystem regelm ig um Sch den an der Einheit durch verschmutzte Filter zu vermeiden 3 Sie sollten das Wasser am Boden der Wasserpumpe auslassen wenn die HP Einhei...

Страница 34: ...32 9 Explosionszeichnung Explosionszeichnung LuxuryBlack i14 LuxuryBlack i16...

Страница 35: ...sring 46 Elektrischer Reaktor 13 Display 47 Wifi Modul 14 Isolierungsplatte 48 Reaktorbox 15 Service Panel 49 Schaltkasten 16 Verdampferheizwiderstand 50 PCB 17 Kompressor 51 Magnetring 18 Rechtes Fel...

Страница 36: ...34 LuxuryBlack i20...

Страница 37: ...ul 14 Display 50 PCB 15 Service Panel 51 Anschlussklemme 16 Bodenschale 52 Clip 17 Kompressor Gummif e 53 Anschlussklemme 18 Kompressor 54 Schaltkasten 19 Kompressorheizwiderstand 55 Magnetring 20 Ver...

Страница 38: ...36 LuxuryBlack iV26 LuxuryBlack iV30...

Страница 39: ...n 16 Service Panel 52 Seitengrill 17 Entladetemperatursensor T6 TH3 53 Elektrischer Reaktor 18 Clip 54 Reaktorbox 19 Sensorhalter 55 Rohr 20 Anschlussklemme 56 Verdampfertemperatursensor T3 TH2 21 Cli...

Страница 40: ...er angegebenen Mindest und H chstwerte 7 Verwendung nicht autorisierter Teile oder Zubeh rteile in Zusammenhang mit dem Produkt 8 Chemische Verschmutzung der Verbrennungsluft oder unsachgem e Verwendu...

Страница 41: ...ind von Ihnen zu tragen 2 F r die R ckgabe von Produkten ist eine vorherige Genehmigung erforderlich Nicht f r die R ckgabe genehmigte Produkte werden Ihnen auf Ihre Kosten zur ckgeschickt 3 Wir repar...

Страница 42: ...schickt 12 Alle Verpackungen die zum Zeitpunkt der Auslieferung an uns besch digt erscheinen werden IN DER VORLIEGENDEN FORM abgelehnt 13 Bitte stellen Sie sicher dass die an uns gesandten Produkte di...

Страница 43: ...41 Swimming Pool Heat Pump User and Service Manual LUXURYBLACK INVERTER...

Страница 44: ...orinated greenhouse gases and handling safety the relevant type and size of equipment Record keeping 1 Operators of equipment which is required to be checked for leaks shall establish and maintain rec...

Страница 45: ...s of the manufacturer and the regulations in application Incorrect installation against the manual implies the exclusion of the entire guarantee The manufacturer declines any responsibility for the da...

Страница 46: ...C O P 8 0 5 8 0 5 8 2 5 8 2 5 8 2 5 C O P in Turbo Mode 4 6 4 6 4 5 4 6 4 5 C O P at 50 capacity 6 8 6 8 6 7 6 8 6 7 General data Compressor type Inverter compressor Voltage V 220 240V 50Hz 1PH 380 41...

Страница 47: ...45 2 Dimension LuxuryBlack i14 LuxuryBlack i16...

Страница 48: ...46 LuxuryBlack i20...

Страница 49: ...47 LuxuryBlack iV26 LuxuryBlack iV30 Unit mm...

Страница 50: ...the water Note Lift the heat pump to install the jet Never overturn the heat pump it could damage the compressor Water Inlet outlet junction 1 Use the pipe tape to connect the water Inlet outlet junc...

Страница 51: ...ncluding a bypass if necessary must be provided by the user or the installer Attention Please observe the following rules when installing the heat pump 1 Any addition of chemicals must take place in t...

Страница 52: ...NTION Never install the unit in a closed room with a limited air volume in which the air expelled from the unit will be reused or close to shrubbery that could block the air inlet Such locations impai...

Страница 53: ...heat exchanger For this reason equipment of this sort must always be fitted in the piping on the downstream side of the heat pump and it is recommended to install a check valve to prevent reverse flow...

Страница 54: ...the flow switch 5 Allow the heat pump and the filter pump to run 24 hours a day until the desired water temperature is reached The heat pump will stop running at this point After this it will restart...

Страница 55: ...low the heat pump s automatic adjustment knob your dealer may need to adjust its initial start up Time delay The heat pump has a built in 3 minute start up delay to protect the circuitry and avoid exc...

Страница 56: ...en will be locked when 30 seconds without operation Water temperature setting Press or to set the water temperature directly Press and at the same time to check water in temperature water out temperat...

Страница 57: ...d to select the functions and press to enter 5 2 5 Heating Cooling Auto mode Select and press to enter press and to choose Heating Cooling Auto mode press again to exit The default mode is Heating mod...

Страница 58: ...for 3 minutes Standby Standby T1 30 It switches to cooling mode Cooling mode T1 28 last for 3 minutes Standby Standby T1 27 last for 3 minutes It switches to heating mode 2 When the heat pump starts...

Страница 59: ...time All error code Remark d4 Frequency limitation code 0 No frequency limit 1 Coil pipe temperature limit 2 Overheating or overcooling frequency limit 4 Drive Current frequency limit 8 Drive voltage...

Страница 60: ...d For example 5 2 9 Time setting Timer setting Select and press to enter press again to Timer on Timer off setting Press to enter and and to select Timer on or Timer off Press to select on off and pre...

Страница 61: ...bient temperature protection PP08 1 Beyond the scope of using environment 2 Sensor abnormality 1 Stop using beyond the scope of using 2 Change the sensor Piping temperature too high protection under c...

Страница 62: ...ormal 6 Power fluctuations within a short time 1 Check the compressor 2 Check the waterway system 3 Check if the power in the normal range 4 Check the phase sequence connection Communication failure b...

Страница 63: ...fan motor damaged change another one 3 Change another fan blade PFC module protection EE16 1 Output exception of PFC module 2 Motor is abnormal or damaged 3 Fan blade is broken 4 Input voltage leap i...

Страница 64: ...r change a new one Ambient Temperature device failure on Driver board EE24 Ambient Temperature device failure Change driver board or main board Compressor phase failure EE25 Compressors U V W are conn...

Страница 65: ...xample below Mode Water out temperature Setting temperature Condition Malfunction Heating mode 36 29 Tout Tset 7 EE04 Over heating protection for water temperature T2 Cooling mode 23 30 Tset Tout 7 PP...

Страница 66: ...ose the wrong mode 2 Figures show defects 3 Controller defect 1 Adjust the mode to proper running 2 Replace the defect LED wire controller and then check the status after changing the running mode ver...

Страница 67: ...65 7 Electrical Wiring LuxuryBlack i14 LuxuryBlack i16 LuxuryBlack i20...

Страница 68: ...66 LuxuryBlack iV26 LuxuryBlack iV30...

Страница 69: ...ermits turning off power at the unit while the unit is being serviced 8 Maintenance 1 You should check the water supply system regularly to avoid the air entering the system and occurrence of low wate...

Страница 70: ...68 9 Exploded view LuxuryBlack i14 LuxuryBlack i16...

Страница 71: ...box 15 Service panel 49 Electric box 16 Evaporator heating resistor 50 PCB 17 Compressor 51 Magnet ring 18 Right panel 52 Magnet ring 19 Base tray 53 Water pump terminal 20 Compressor rubber feet 54...

Страница 72: ...70 LuxuryBlack i20...

Страница 73: ...52 Clip 17 Compressor rubber feet 53 Power terminal 18 Compressor 54 Electric box 19 Compressor heating resistor 55 Magnet ring 20 Evaporator support 56 Magnet ring 21 Reactor 57 4 way valve 22 Compr...

Страница 74: ...72 LuxuryBlack iV26 LuxuryBlack iV30...

Страница 75: ...anel 52 Side grill 17 Discharge temp sensor T6 TH3 53 Reactor 18 Clip 54 Reactor box 19 Sensor holder 55 Dehydrator filter 20 Power terminal 56 Evaporator temperature sensor T3 TH2 21 Clip 57 Evaporat...

Страница 76: ...e product with a flow rate outside the published minimum and maximum specifications 7 Use of components or accessories not designed or made for this product 8 Chemical contamination of the air used by...

Страница 77: ...hipping service of your choice 4 If you choose express shipment by a shipping service selected by you you are responsible for paying the shipping costs Return procedure 1 Before requesting an RMA numb...

Страница 78: ...n shipments at all will be accepted without an RMA number Absolutely no exceptions to this rule are allowed 11 An RMA number remains valid for just 21 calendar days after it is assigned We reserve the...

Страница 79: ...77...

Страница 80: ...r smart phone can use the 3G 4G network to control pool heat pump remotely By Alsavo Pro APP you can turn heat pump on or off adjust water temperature change mode timer setting parameter setting and m...

Страница 81: ...ick Next and Enter the current WIFI password to connect The connection process may last for 30s to 120s depends on the wifi Nickname and password interface only appear one time when new heat pump firs...

Страница 82: ...80 2 3 The main interface...

Страница 83: ...s to switch Auto mode heating cooling 3 Timer Setting Click at first time it turns Timer on and off will be activated together Then choose desired time in timer on and timer off lastly click OK to con...

Страница 84: ...82 Parameter setting 1 There are 2 modes option for Water pump operating 1 Always running 0 Depends on the running of compressor 2 Inlet water temperature calibration 9 0 to 9 0 3 Temperature unit or...

Страница 85: ...83 4 When do the re set to factory default setting pop up tips whether you want to reset it 5 Switch the Frequency In heating or cooling mode there are 3 frequency Silent Smart Powerful for options...

Страница 86: ...84 While in Auto mode its default frequency is Smart 6 Malfunction If error occurs the Malfunction icon turns red Click it to check the Error...

Страница 87: ...ously updated to the APP 8 Check device information In the main interface click the upper right Alsavo Pro The Device info will show up 9 Revise the heat pump info in the homepage Click you could rena...

Страница 88: ...86...

Страница 89: ...87 A0155PXI01...

Отзывы: