Installation Manual
Maipu Confidential & Proprietary Information
Page 16 of 21
Picture 3-1 Installation Picture
Step 4: The hanger of the switch is not used to bear the load but fasten. Switch is installed
in a 19” cabinet. There must be slides in chassis (fastened in frame) to support switch
Picture 3-2 Installation Picture
Note
The heaviest device should be installed near the bottom of the cabinet.
For cooling, there should be 1U distance between two installed devices.
3.3 Cable
This chapter describes how to connect cable to switch.
3.3.1 Connect to Switch Console Port
There is a EIA/TIA-232 console port on SM3300-28FX switch. User can use this port to
configure the switch.
Step1: A character terminal which can be a RS-232
Step2: Connect RS-232 port to console port
3.4 Connect to Ground
SM3300-28FX Switch well-connected can protect switch from lightning and jamming,