MTC maintronic GmbH - Schweinfurt | Germany - www.maintronic.com
CRD400 INS - Manual
Date: 09.07.2021
Page
20
1.
2.
3.
4.
Reset to factory default settings
The dimmer can be reset via the device button and the settings will be restored to the factory
default settings.
For a reset, the device must not be paired with a Casambi network.
Step by step guide
Remove the device from any existing Casambi network.
Press the device button for 20 seconds
After 20 seconds the device will be reset and the LEDs will flash.
After the reset an automatic calibration takes place
Content of this page
Related content
Casambi Sensors and
Parameters
NOTE
The following values are reset during a reset:
Casambi Configuration
Parameters are set to default values
Measure mode = Automatic
Push-Button-Style = Comfort
Sensors values
Total consumed
On-Time Load
On-Cycles Load
The System Reset function is only active for 60 minutes after the device is switched on.
To perform a reset after this time, the device must be restarted.