Casambi Sensors and Parameters
Sensors
With the sensors, various states can be queried and displayed in the Casambi APP.
Casambi
Sensors
Description
Can be
Reset
Value
range
Units
Total consumed
Total energy consumed in Wh
yes
0 ...
1.000.000
Wh
Current Power
Momentary power consumed by the load
0 ...
1.000.000
Wh
Load Current
Momentary RMS load current in mA
0 ...
1.000.000
mA
Temperature
Displays the momentary temperature of the
unit.
°C
On-Time
Dimmer
Operating hours device
no
0 ...
1.000.000
h
On-Time Load
Operating hours of the lamp / load
yes
0 ...
1.000.000
h
On-Cycles
Device
no. of Power-on cycles of the device
no
0 ...
1.000.000
cycles
On-Cycles Load
no. of Switching on cycles of the load / lamp
yes
0 ...
1.000.000
cycles
Phase Angle
Phase Angle = current phase angle of the
dimming output
0 ° > Load is switched off
1-179 ° > Phase cut is applied
180 ° > Load is switched permanently
on
0 … 180°
degree
(360)
System Status
System Status - Error Code
From this error code the System Info is
derived.
0, 1, 2, 4, 8,
16, 32
Leading Edge
0 > Trailing edge phase cut is used
1 > Leading edge phase cut is used
0, 1
Parameters
Parameters can be set for the dimmer functionality.
Casambi
Parameters
Description
Value
range
Units
Unlock/ Lock
Settings
To unlock the following Expert parameters
locked
unlocked
Measure Mode
Here a measure mode can be preset with which a new calibration
starts.
Automatic
Trailing
Edge
Leading
Edge
Zero
Cross
Switch
Start
Measurement
Start new calibration
Reset statistics
Delete statistics
Push-Button-
Style
Behavior of the PushButton input
>>> See Push-button style
Comfort
Standard
Content of this page
Related content