Maintronic Casambi CBA UP Скачать руководство пользователя страница 5

          www.maintronic.de                  

5

WARNING

For your own safety, read all instructions and in

-

formation  in  this  manual  carefully  before  initial 

operation. Keep this manual for future reference.

The  instructions  are  an  integral  part  of  the  pro

-

duct and must be handed to the end customer.

All  information  and  instructions  in  this  manual 

must be observed completely and in detail. The 

manufactuer is not responsible for any direct or 

consequential damage that results from disregar

-

ding any information in this manual.

Waste disposal

In accordance with European Directive 2002/96/

EC (it`s) not longer usable electronic devices and 

defective  or  used  batteries  (European  Directive 

2006/66EG) must collected separately and dispo

-

sed by an environmentally sound recycling.

This symbol indicates that electrical and elect-

ronic equipment must be disposed of separately 

from normal waste at the end of its operational 

lifetime.

Should these product  are  no  longer  be  useable, 

the user is required by law to dispose of old ap-

pliances separately from their household waste e. 

g. at a local authority collection point or recycling 

center.

 CE-marking

The devices comply with the EU directives appli

-

cable at the time they are placed on the market. 

DANGER

The unit must only be installed and serviced by a 

proven electrican specialist, in accordance of all 

relevant regulations, safety and accident preven

-

tion directives of the country.

 

 

Be sure that the existing mains voltage corres

-

ponds with the specified operating voltage befo

-

re operating the device.

 

 

Risk of electric shock. Do not operate the device 

without a cover. Even when switched off, voltage 

may be present at the outputs. When working on 

the device or connected loads, always disconnect 

the upstream fuse from the power supply. 

 

Apply the „Five Safety Rules“  

(DIN VDE 0105, EN 50110):

1.  Disconnect

2.  Secure against being switched on again

3.  Determine absence of voltage

4.  Ground and short circuit

5.  Cover or isolate nearby live parts

Only install the device in places with a good 

ventilation and without humidity or high tempe

-

ratures. Do not expose the unit to rain or snow. 

Do not operate the unit near heat sources, e.g. 

radiators.

If any of the following occurs, do not operate the 

device without first checking it:

•  if objects have fallen or liquid has been 

spilled into the unit.

• 

if the device has been exposed to rain.

• 

if the device does not operate normally or 

with altered characteristics.

• 

if the device has been dropped or has a bro-

ken housing.

For cleaning only use a dry, soft cloth, by no me

-

ans liquids.

2.  

Safety information

Содержание Casambi CBA UP

Страница 1: ...CBA UP Casambi blind actuator Valid from version H Hardware F Firmware 10 750 CBA UP H2 F2 5 10 752 CBA UP H1 F2 5 10752_MA_en_A4_CBA UP_20210310 Manual EN EN...

Страница 2: ...o a network 11 4 3 1 Profile A CBA Blind Drive blind Adjust slats 12 4 3 2 Profile B CBA Blind Buttons Drive blind Adjust slats additional switches 13 4 3 3 Profile C CBA Shutter Roller blind drive 14...

Страница 3: ...maintronic assumes no liability or warranty regar ding this document or the products described 1 1 About this Document Congratulations and thank you for choosing this maintronic product and the trust...

Страница 4: ...that can lead to material damage Either to the product itself or to other objects in the environment WARNING The signal word WARNING indicates a possibly imminent danger If it is not avoided death or...

Страница 5: ...the time they are placed on the market DANGER The unit must only be installed and serviced by a proven electrican specialist in accordance of all relevant regulations safety and accident preven tion d...

Страница 6: ...s allow e g to group 5 blinds on one side of a building and to operate them together In addition automated up and down movements can be programmed as a time controlled scene If you need help with conf...

Страница 7: ...e actuator once and then recalled see 4 4 Driving to an absolute position With a drive to an absolute position any hori zontal position can be approached The absolute position is controlled by a slide...

Страница 8: ...commended to use the dee pest junction boxes possible Depending on which pushbutton attachments are used up to 30 mm of additional installation space is required For installation in cavity or switch b...

Страница 9: ...re with ferrule Figure CBA UP 10 750 Figure CBA UP 10 752 NOTE The relay outputs are mutually locked to ensure that only one drive path is active at a time motor protection 1 N Neutral conductor 4 Rel...

Страница 10: ...mined Before programming a Casambi profile must be selected by default the profile CBA Blind But tons is set Profiles for venitian blinds CBA Blind Operation via APP Move blind to absolute position Ad...

Страница 11: ...or your ap plication from the following pages the device will be added to a Casambi network Tap on the menu item Change profile Tap on the menu item Add to Network The selected profile is now loaded S...

Страница 12: ...e Drive time for blind operation 0 255s seconds 60s default Angle Time Drive time for slat adjustment 0 65535ms milliseconds 2000ms default Swap Controls Up Down Logical invert of drive direction No Y...

Страница 13: ...e Down ON OFF Toggle Angle Slat angle Push Button Profile parameter Parameter Casambi Description parameter Value Default Notes Drive Time Drive time for blind operation 0 255s seconds 60s default Ang...

Страница 14: ...tion Slider 0 100 Profil Parameter Parameter Casambi Description parameter Value Default Notes Drive Time Drive time for roller blind 0 255s soconds 60s Default Swap Controls Up Down Logical invert of...

Страница 15: ...drive Up ON OFF Toggle Down Single drive Down ON OFF Toggle Profil parameter Parameter Casambi Description parameter Value Default Notes Drive Time Drive time for roller blind operation 0 255s second...

Страница 16: ...Notes Drive Time Drive time for roller blind operation 0 255s seconds 60s default Function A Function B Function for button A Function for button B Not in Use Not in Use Blind Up Roller blind Up Blin...

Страница 17: ...letely closed to 0 comple tely open can be measured again 3 Enter the measured time plus approx 1 se cond as a buffer in the device settings under parameter Drive Time Setting the slat position Angle...

Страница 18: ...as a group one device of the group must be defined as the master For the desired master the push button style must be set to Group Button The other maintronic devices in the group are automatically sl...

Страница 19: ...signed with desired functions In order to do this the following steps are necessary 1 Open Casambi app and tap on More 2 Open item Switch 3 Select device 4 For example program switch with single funct...

Страница 20: ...indication of the horizontal position is no longer correct Only a travel to one of the end points OT UT via the control from Casambi synchronizes the display with the real position again As soon as a...

Отзывы: