![Main First Technologies VR604 Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/main-first-technologies/vr604-series/vr604-series_user-manual_3697929044.webp)
DVR operation manual
40
【
Bit Rate Type
】
You can choose limited code stream or variable code stream. When you choose
the variable code stream there are six image quality options.under the limited code stream
,
you can
choose the code stream manually.
【
Bit Rate
】
Set the code stream value to modify the image quality. The larger code stream value the
better image quality.
D1
(
512~2560kbps
)
HD1
(
384~2048kbps
)
CIF
(
64~1024kbps
)
, QCIF(64~512kbps)
【
Frame Interval
】
can choose the range 2~12s
【
Video/Audio
】
When the icons are all in reverse displayed, the video file is video and audio
multiplex stream.
Extra stream Settings
【
Extra stream
】
is used for client side monitoring & mobile monitoring.
【
Channel title
】
select channel title and then to choose whether need enable video & audio. The
resolution, frame rate, bit rate type settings is the same as main stream.
5.4.3 Network setup
Pic 5.16 Network
【
Net Card
】
You can choose cable network card or wireless network card.
【
DHCP Enable
】
Obtain IP address automatically(not suggested).
Note
:
The
DHCP server need pre-installed
【
IP address
】
Set the IP address. Default: 192.168.1.10.