Maiman Electronics
MBL1500B
18
Table 15. The format and codes of errors
Error (returned
command)
Reasons
E0000
1) Internal buffer of device is overflowed
2) Cannot find <CR> (0x0D) or\and <LF> (0x0A)
3) Format of command is invalid
E0001
1) Unknown command (it does not P- or J-type command)
2) The device failed to correctly interpret a command
Table 16. Available parameters and its description
Action
R/W
HEX-
number of
parameters
Frequency
(0,1 Hz)
Value
R/W
0100
Minimum
R
0101
Maximum
R
0102
Duration
(0,1 ms)
Value
R/W
0200
Minimum
R
0201
Maximum
R
0202
Current
(0,01 А)
Value
R/W
0300
Minimum
R
0301
Maximum
R
0302
Measured value (0,1 А)
R
0307
Current set
calibration (0,01%)
1
Value
R/W
030E
Voltage (0,1 V)
Measured value
R
0407
State of the device
(bit mask)
Start (Enable)
0008h
W
0700
Stop (Disable)
0010h
Internal current set
0020h
External current set
0040h
External Enable
0200h
Internal Enable
0400h
Allow Interlock
1000h
Deny Interlock
2000h
Deny NTC Interlock
4000h
Allow NTC Interlock
8000h
1