Maier MHI-6500 Скачать руководство пользователя страница 4

3

ROTATE Option

FUNCTION Option

TIME SETTING

1-hour       2-hour        4-hour       5-hour       6-hour        7-hour   

  Inside the unit there is a circulating fan and a U.V. lamp. The fan circulates and purifies room air while the U.V. lamp cleans and 

  sterilizes air at the same time. The unit runs the following sequence of functions according to the number of times you press the 

FUNCTION button:

Fan ON / U.V OFF

Fan OFF /U.V. ON

Fan ON / U.V. On

Fan OFF / U.V. OFF

Press the rotate button, the unit will rotate in 90-degree angle, swinging back and forth. Press again and the rotation will end.  

   Press the TIME SETTING button when the unit is ON. According to the number of times you press the button, the 
   setting will run in the following sequence as indicated by the LED:

Remote Control

   This appliance can operate using a remote control. A shelf for the remote control is provided at the top of the unit to 
   avoid accidental loss.
   The operation of remote control: Each press on the buttons of the remote control 
   results in "BEEP" sound of different lengths (short or long), which guide you to select 
   your preferred working status of the machine.

Operation ON/OFF 

Operation Setting Option

Negative oxygen ion Hi/Med/Lo options:

   Press the NEGATIVE OXYGEN ION button, the unit will then release negative ion with ion concentration level according to the 

   number of times you press (in a cycle of LO      MED      HI), as indicated by the LED.

   Under HI: the appliance continues to release negative oxygen ion.

   Under MED: the unit runs a cycle of operating 60 seconds then resting 60 seconds

   Under LO: the unit runs a cycle of operating 15 seconds then resting 105 seconds

Set-Up and Operation

Place the Unit at least 30cm from the wall and in a location where children cannot stare directly into the unit at a close range. 

Plug into a grounded domestic outlet. Press the ON/OFF button to initiate operation and the LED turns solid blue. Press the 
ON/OFF button again to stop operation. 


Under MED and LO, negative oxygen ion is released alternately.
Choose the proper operation setting according to room size and air pollution level. 

ROTATE

MODE

ON/OFF

TIMER

O  ION

ON/OFF MODE 

O

ION 

ROTATE 

ON

1 short   

Low

1 short 

Fan ON, UV OFF

1 short 

ON

1 short 

OFF

2 longs 

Med

2 shorts 

Fan OFF, UV ON

2 shorts 

OFF

1 long 

 

High

3 shorts 

Fan ON, UV ON

3 shorts 

 

 

 

Fan OFF, UV OFF

1 long 

 

TIMER 

Hours to Stop 

BEEP sound 

1 short 

2 shorts  3 shorts  4 shorts  5 shorts  6 shorts 

7 shorts 

 

6500 IM.indd   4

6500 IM.indd   4

2008-5-9   2:05:27

2008-5-9   2:05:27

Содержание MHI-6500

Страница 1: ...et carefully MAIN FEATURES MAIN FEATURES Long electrostatic dust collector Powerful UV germicidal technology Remote control provides convenient use Independent fan rapidly circulates indoor air Negative ions and activated oxygen remove odors and smoke No need to replace filter easy for cleaning 90 degree rotation extends purification coverage Use advanced ionic air movement technology 6500 IM indd...

Страница 2: ...r cord must only be replaced by qualified service personnel with the spare power cord provided To prevent electric shock do not dismantle repair or modify this product In case of malfunction contact authorized maintenance center Do not use in places where flammable and explosive materials are stored Do not place machine in the shower or places where water may wet the machine to prevent electric sh...

Страница 3: ...Collector Dust Collector Button Air Output Vent Inbulit Fan Front Grill Air Intake Vent Inbulit UV Lamp Rear Grill Bottom Stand ON OFF Power Switch Names of Parts FLOW 6500 IM indd 3 6500 IM indd 3 2008 5 9 2 05 23 2008 5 9 2 05 23 ...

Страница 4: ...g Option Negative oxygen ion Hi Med Lo options Press the NEGATIVE OXYGEN ION button the unit will then release negative ion with ion concentration level according to the number of times you press in a cycle of LO MED HI as indicated by the LED Under HI the appliance continues to release negative oxygen ion Under MED the unit runs a cycle of operating 60 seconds then resting 60 seconds Under LO the...

Страница 5: ...ess of pulling the dust collector out and pushing it back The cleaning plates will scrape off the dust on the metal pointers as you move the dust collector up and down The interior of the appliance also accumulate dust Before putting the dust collector back after cleaning invert the entire unit for a few times to get rid of the accumulated dust The exterior of the unit can be cleaned using mild de...

Страница 6: ...d see fig 1 and fig 2 Softly turn the UV lamp and slide it from its fixture Replace with a new lamp of the same model The unit will not function while the dust collector is removed and or the back cover is removed Always restore the dust collector and the back cover to their respective positions after cleaning fig 1 fig 2 Cleaning and Protection 6500 IM indd 6 6500 IM indd 6 2008 5 9 2 05 47 2008 ...

Страница 7: ... Plug looses doesn t contact well to the socket Plug into electric socket Plug into electric socket tightly and completely Operating stop midway Operation period set by the timer arrives its end No malfunction restart the unit or reset the timer Loud noise Dust collector is fully filled with dirt Operate in humid area Clean the dust collector Place the machine to dry place UV lamp is not lit UV la...

Страница 8: ...e year from the date of purchase enjoy free repair or replacement of parts presentation of this guarantee if it is attested by our company that malfunctlon or damage to the device and or parts occurs under normal running condition 2 The guarantee does not cover the damages that are attributable to self dismantling and assembling unauthorized operation not found in the instruction random change of ...