![Maier DX Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/maier/dx-series/dx-series_operating-instructions-manual_3678460034.webp)
S Specifications and Spare Parts Series DX / DXS
3
.
Initial lubrication
and relubrication
3 / 16
© 2011 by Christian Maier GmbH & Co. KG Maschinenfabrik
This document may not be copied or disclosed to third parties.
All rights, including copyright and property rights, reserved by Maier.
S-DX_en – Version 12 –05.07.2011
S
3.
Initial lubrication and relubrication
Lubricants
The rotary joints are factory-lubricated with PETAMO GY 193 by Klüber Lubrication KG.
(Phone: +49-(0)89-7876-271 |
www.klueber.com
)
Relubrication at nipple – used grease escapes via the bearing housing.
Attention:
Warranty is forfeited when using greases not approved by us.
Volume at …
DN
mm
10
15
20
25
32
40
50
65
80 100 125 150
Initial
lubrication (Q
E
)
Bearing 1 cm
3 *1
1,5
3
5
6
12
15
28
45 100 120 210 300
Bearing 2 cm
3 *1
1,5
3
5
6
12
15
28
45 100 60 105 150
Relubrication (Q
N
)
Rotary
joint
Strokes
*
2
2
4
5
6
8
10
15
20
40
50
70 100
*1 Grease volume as recommended value for
one
bearing (spaces filled to 50%)
*2 Strokes of a grease gun as per DIN 1283 with 1.2 cm
3
per stroke and
rotary joint
The relubrication intervals are recommended values. Reduce the intervals to one half in the
case of exceptional operating or environmental conditions (such as high pressures or loads,
heavy machine vibrations or polluted bearing grease). Experiences of the owner/operator can
be considered in optimizing the lubrication intervals.
Temperature
up to 80 °C
80 °C to 120 °C
120 °C to 140 °C
140 °C to 150 °C
Intervals
Factory lifetime lubrication Every 6 months
Every 12 weeks
Every 2 weeks
4. Extracting
tools
DX / DXS
Product no.
10 1190325
15 1190326
20 1190327
25 1190328
32 1190329
40 1190330
50 1190331
65 1190332
80 1190333