B Operating Instructions for Rotary Joints Series DX/DXS
6
.
Mounting
17/27
© 2011 by Christian Maier GmbH & Co. KG Maschinenfabrik
This document may not be copied or disclosed to third parties.
All rights, including copyright and property rights, reserved by Maier.
AB-DX_en – Version 08 – 01.03.2011
B
Aligning the rotary joint in case of sealing with flat packing
B-19
1.
Place dial gauge [M] from the idle machine frame
[MG] onto the rotary joint.
2.
Rotate roller [W] until the dial gauge is at the bottom
dead center [UT]. Mark the pointer position.
3.
Rotate roller [W] until you reach the upper dead
center [OT].
4.
Tighten the bottom screws [Su] until the dial gauge
is in the center position.
5.
Repeat this alignment process until you reach the
concentricity tolerance specified in the table below.
6.
Tighten the screws with the permissible torque as
per section "Specifications and Spare Parts"!
Permissible concentricity tolerance
n
(min
-1
/rpm)
DN
≤
100
≤
400
> 400
10 – 50
± 0.25 mm
65 - 150
± 0.1 mm