8.

 Installation, Electrical 

connection 

 

DANGER 

Danger to life from  
electric shock 

 Switch the mains fuse off. 

 Position a warning notice to 

avoid the unit being accidentally 
switched back on. 

  NOTICE 

Danger of short-circuits caused 
by damp if the connection cable 
is not inserted in the housing 
correctly. 

 Feed the connection cables into 

the housing through the PG 
screw-connections. Ensure that 
the rubber seals tightly surround 
the cables. 

 Pull off the rotary knob [10], loosen the  

4 screws and remove the cover [9]. 

 Fix the housing lower part [1] to the wall 

with four screws (

 arrow, Chapter 3.1). 

Suitable mounting material is to be 
supplied by the customer. 

 Set operating mode to heating or cooling 

with plug jumper [3] (factory setting heating). 

 Set the differential gap with the potentio-

meter [4] (setting range 0.2...5 K). 

 Feed the connection cables into the 

housing through the PG screw-connections 
and wire the cables to the connecting ter-
minal [5] according to the wiring diagram. 

 Locate the cover [9] onto the housing lower 

part [1], screw it into place with the 4 
screws and replace the rotary knob [10]. 

Position the cover [9] correctly. Make 
sure that the shaft [8] is not damaged. 

 Switch the mains fuse on. 

 Install the fan(s) in accordance with their 

operating instructions. 

 

8.1 Start-up 

 Check that the technical data has been 

adhered to, by reference to the rating plate. 

 Set the setpoint temperature using the 

rotary knob [10].  

 Carry out a function test. 

The switching state of the relay can 
be checked by reference to LED [2]. 
The LED lights up if the relay is 
energised (terminals 4 and 5 closed). 

 

9.

 Maintenance 

The unit is maintenance-free. 

 

10.

 Dismantling 

 

DANGER 

Danger to life.  
Unit is powered up. 

 Switch the mains fuse off. 

Dismantling should only be carried out by a 
trained electrician. 

 

11.

 Disposal 

 Dispose of the unit once it has reached the 

end of its working life according to the 
regulations valid where you are. 

Do not dispose of it in domestic 
waste! 

The unit contains in part 

material that can be recycled and in 
part substances that should not end 
up as domestic waste. 

 

12.

 Wiring diagram 

 
 
 
 
 
 
 
 
 
 

i

i

GB 

Содержание TH 10

Страница 1: ...Thermostat TH 10 Montage und Betriebsanleitung Mounting and Operating instructions www m aic o v ent ilat oren c om D GB...

Страница 2: ...n K hlen 4 Potentiometer Schaltdifferenz 5 Anschlussklemme 6 PG Verschraubung 7 Temperatursensor mit Anschlussleitung 2 m lang 8 Drehknopfwelle 9 Abdeckung 10 Drehknopf Solltemperatur 3 2 Bestimmungsg...

Страница 3: ...einer fest verlegten elektri schen Installation anschlie en Vorrichtung zur Trennung vom Netz mit mind 3 mm Kontakt ffnung je Pol erforderlich Ger t nur mit auf Typenschild angegebe ner Spannung und F...

Страница 4: ...chlussklemme 5 gem Schaltbild verdrahten Abdeckung 9 auf das Geh useunterteil 1 aufsetzen mit den 4 Schrauben verschrau ben und Drehknopf 10 aufstecken Abdeckung 9 lagegerecht aufsetzen Darauf achten...

Страница 5: ...terminal 6 PG screw connection 7 Temperature sensor with 2 m connection cable 8 Rotary knob shaft 9 Cover 10 Setpoint temperature rotary knob 3 2 Intended use Thermostat for controlling fans depending...

Страница 6: ...ialists Only connect the unit to a permanent electrical installation Fixture for disconnecting from mains with at least 3 mm contact opening needed per pole The unit may only be operated using the vol...

Страница 7: ...rding to the wiring diagram Locate the cover 9 onto the housing lower part 1 screw it into place with the 4 screws and replace the rotary knob 10 Position the cover 9 correctly Make sure that the shaf...

Страница 8: ...8 Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 694 447 technik maico de 0185 0884 0001_RLF 3_09 11_DSW s 11_E 09...

Отзывы: