MA 1 Operating Manual 

 

10                                                 

8100216-3

 (D-0100192) 

8.

 

Warranty and Disclaimer 

Warranty, Maintenance and After-Sales Service Hardware 

The  MA  1  audiometer  is  guaranteed  for  1  year.  This  warranty  is  extended  to  the 
original  purchaser  of  the  instrument  by  MAICO  through  the  Distributor  from 
whom  it  was  purchased  and  covers  defects  in  material  and  workmanship  for  a 
period  of  one  year  from  date  of  delivery  of  the  instrument  to  the  original 
purchaser. 
 
The  audiometer  may  be  repaired  only  by  your  dealer  or  by  a  service  center 
recommended by your dealer. We urgently advise you against attempting to rectify 
any faults yourself or commissioning non-experts to do so. 
 
In  the  event  of  repair  during  the  guarantee  period,  please  enclose  evidence  of 
purchase  with  the  instrument.  In  order  to  ensure  that  your  instrument  works 
properly,  the  audiometer  should  be  checked  and  calibrated  at  least  once  a  year. 
This check-up needs to be conducted by your dealer. 
 
Calibration  instrument  or  other  information  that  will  assist  service  personnel  to 
repair  those  parts  of  the  audiometer  that  is  designated  as  repairable  by  service 
personnel will be available on request. 
 
When  returning  the  instrument  for  repairs  it  is  essential  to  also  send  the 
headphone  and  other  accessories.  Send  the  device  to  your  dealer  or  to  a  service 
center authorized by your dealer. Please also include a detailed description of the 
faults. 
 
In  order  to  prevent  damage  in  transit,  if  possible  please  use  the  original  packing 
when returning the instrument. 

 

 

 

Содержание MA 1

Страница 1: ...MAICO Diagnostics 10393 West 70th Street Eden Prairie MN 55344 USA Toll Free 888 941 4201 MA 1 Operating Manual...

Страница 2: ......

Страница 3: ...ions 6 5 Battery Operation 6 6 Front Panel Controls and Display 7 7 Audiometric Testing 8 7 1 Instructing the Patient 8 7 2 Test Environment Ambient Noise 8 7 3 Conducting the Test 9 8 Warranty and Di...

Страница 4: ......

Страница 5: ...info maico diagnostics com Internet www maico diagnostics com Copyright 2015 MAICO Diagnostics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any me...

Страница 6: ...1 to ensure its user friendliness meaning that its operation is simple easy to learn and to understand The MA 1 is an ultra portable audiometer and a perfect choice for on the go hearing professionals...

Страница 7: ...s or schools 3 Description The MA 1 screening audiometer is designed to be a device for screening for hearing loss Output and specificity of this type of device are based on the test characteristics d...

Страница 8: ...headphone complement each other and share the same serial number i e 63252 Therefore the instrument shall not be used with any other headphone prior to recalibration Recalibration also needs to be con...

Страница 9: ...horoughly inspect the exterior of the shipping box for any sign of damage or tampering Should any damage be noted please notify the carrier immediately If the content box has been damaged during trans...

Страница 10: ...teries 1 Pull the tab on the battery compartment and remove panel 2 Insert 2 AA batteries oriented as shown 3 Reposition the panel and snap the tab back into place Battery Life Maico Recommends using...

Страница 11: ...3 D 0100192 6 Front Panel Controls and Display Figure 3 1 Power button and R L Ear Selector 2 LED Ear Indicator 3 LED Level Indicator 4 dB Level selector buttons 5 Frequency selector buttons stimulus...

Страница 12: ...placement of the earphone cushion on the ear i e hair earrings eyeglasses hearing aids etc b Adjust the headband so the earphone cushions are centered over the ears and the head The earphone cushions...

Страница 13: ...atient responds Once the patient responds lower the tone by 10dB until he she does not respond Continue in this down 10dB up 5dB pattern until a threshold is established or screening protocol has been...

Страница 14: ...o so In the event of repair during the guarantee period please enclose evidence of purchase with the instrument In order to ensure that your instrument works properly the audiometer should be checked...

Страница 15: ...ly contaminated it is strongly recommended to remove them from the transducer before they are cleaned with a disinfectant The use of organic solvents and aromatic oils must be avoided Always disconnec...

Страница 16: ...provided with the instrument 2 Conduct similar tests with several young adults on whom you will be able to make subsequent retests recording these on audiogram cards also 3 File these audiogram cards...

Страница 17: ...t an annual inspection and calibration should be performed The annual check ups can be performed by one of MAICO s authorized service centers 11 2 Instrument Handling The instrument should be checked...

Страница 18: ...m at full intensity Rise fall Times 35 msec Calibration Air Conduction ISO 389 1 ANSI S3 6 Warm Up Time None Dimensions W x D x H 6 35 x 15 24 x 2 22cm 2 5 x 6 x 7 8 inches Weight 2 1 lbs with accesso...

Страница 19: ...acture yyyy Registration Label Address of Manufacturer Registration Label Package Label IFU Return to Authorized Representative Registration Label B Patient Applied Part according to IEC60601 1 Regist...

Страница 20: ...ons are subject to change without notice MAICO Diagnostics 10393 West 70th Street Eden Prairie MN 55344 Phone 1 888 941 4201 Fax 952 903 4100 e mail info maico diagnostics com Internet www maico diagn...

Страница 21: ......

Страница 22: ...8100216 3 D 0100192 06 15...

Отзывы: