6. System and product information
10
Covers: Functions
ER-A
ER-AK ER-AH ER-AB
Filter change display (6 months) with TimeStrip
●
Filter change display (6 months) with LED
●
●
●
Controller with time module
●
●
●
Control with fully automatic humidity control: Extraction
takes place automatically if the specified switch-on humidity
is exceeded
.
●
Control with motion detector. Full load level
after motion is detected (range of motion of the motion
sensor is 5 m)
●
Barrier-free product, as the fan switches itself on and off
automatically
●
●
Not speed-controllable
●
●
●
●
Electrical plug connection for quick connection
of the ER EC with ER GH housing and ER-AK, ER-AH
or ER-AB with the ER EC fan insert.
●
●
●
Air volume – base load 30 m³/h for continuous operation
●
●
●
●
Air volume of the base load and full load levels can be set
●
●
●
Additional air volumes that can be set in base load: 20 m³/h,
40 m³/h and full load 100 m³/h
●
●
●
Full load level on/off via light switch or separate switch.
During manual operation (e.g. using light switch), the start
delay and overrun time apply.
●
●
●
●
Full load operation (60 m³/h) with start delay of 60 seconds
and overrun time of 15 minutes, non-adjustable
●
Full load operation (60 m³/h), start delay can be set with
0, 30,
60*
, 90 or 120 seconds
●
●
● **
Overrun time of the full load level can be set for 0, 3, 6,
15*
, 24 or 30 minutes
●
●
●
Adjustable interval control for ventilating rooms that are
not regularly used. Time interval can be set for
0*
, 1, 2, 4,
6 or 12 hours, 10 min. operating time per interval
●
●
●
Interval control can be switched off.
●
●
●
Switching option: The base load can be switched on or
off by an additional switch (see the wiring diagrams in
chapter 18).
●
●
●
●
* Factory setting: Tolerance of time details max. ± 5 %
** For the ER-B, the start delay only affects the light switch operation