Preface
19
ER-A standard cover:
1 Cover – upper part
2 Cover – lower part
3 Timestrip (→ Title
page)
ER-AK comfort cover
1 Cover – upper part
4 Cover – lower part
with touch control
unit
ER-AH cover with humidity control
1 Cover – upper part
5 Cover – lower part
with touch control
unit
6 Humidity sensor
(rear side cover)
Cover with ER-AB motion detector
7 Cover – upper part
8 Cover – lower part
with touch control
unit
9 Motion sensor
Overview figure
10 Accommodation
mounts (3 pieces)
11 Locking hook (3
pieces)
12 Sealing plugs – mo-
tor board interface
(
ER-AK
,
ER-AH
,
ER-AB
)
13 Fan insert with rat-
ing plate
14 Hole for central
screw
15 Lower part of cover
(2, 4, 5, or 8)
16 Central screw, self-
tapping
17 Air filter
18 Upper part of cover
(1 or 7)
Preface
Please read the instructions carefully before in-
stalling and using for the first time. Follow the in-
structions. Pass these instructions on to the
owner for safekeeping.
1 Scope of delivery
• Central screw
• Air filter
• Installation and operating instructions
ER-A
Article no.
0084.0361
• Standard cover: Lower and upper part of cover
• Time strip on title page of these instructions
ER-AK
Article no.
0084.0362
• Comfort cover: Lower and upper part of cover
ER-AH
Article no.
0084.0363
• Cover with humidity control
• Lower and upper part of cover
ER-AB
Article no.
0084.0364
• Cover with motion detector
• Lower and upper part of cover
For accessory components with more de-
tailed information and order numbers:
2 Specialist installer qualifications
Installation may only be carried out by
trained
specialists
who have the necessary knowledge
and experience in
ventilation engineering
. The
unit must be connected in accordance with the
national technical approval.
Only a
qualified electrician
is permitted to work
on the electrics. You are deemed a qualified elec-
trician if you are familiar with the relevant stand-
ards and guidelines, can competently and safely
connect units to an electrical power supply in line
with the Wiring diagrams and are able to recog-
nise and avoid risks and dangers associated with
electricity on the basis of your technical training
and experience.
3 Intended use
ER EC
fans are used to extract air from interior
bathrooms and toilet rooms, storage rooms or
open-plan kitchens (with outside windows), for ex-
ample in multi-storey residential buildings, retire-
ment homes or hotel complexes.
Installation in a ventilation shaft, in the wall, front
wall or a suspended ceiling is permissible.
The fans can be used as standalone units or for
toilet seat air extraction (according to
DIN 18017-3).
The fans are only intended for domestic use and
similar purposes.
Содержание ER-A
Страница 3: ...System bersicht 3 System bersicht...
Страница 18: ...System overview 18 System overview...
Страница 32: ...Vue d ensemble du syst me 32 Vue d ensemble du syst me...
Страница 48: ...Pregled sustava 48 Pregled sustava...
Страница 62: ...Przegl d systemu 62 Przegl d systemu...
Страница 78: ......
Страница 79: ......