o ensure the maximum application range, the insulated handle between both measuring arm holders must  be

 removed.

 In

 addition

 the

 insulated

 handle

 and

 the

 fixed

 measuring

 arm

 holder

 must

 be

 removed

 from

 

the guide tube, reassembly in the reverse order

Attention!

In

 order

 to

 prevent

 damage

 to

 the

 guide

 tube,

 it

 is

 imperative

 that

 when

 fixing

 the

 the

 insulated

 handle

 that

 

the screws in the groove of the guide tube are submerged.

To extend of the application range, the measuring elements are rotated through 180°. The application ranges can deviate depending upon measuring anvils

7.  Technical Data

Application 

range internal

mm

Application 

range  internal  extended

mm

Application 

range

 

external

mm

Application 

range

 external  extended

mm

Measuring 

range

moveable 

probe

mm

Measuring 

force

N

Order no.

30

-

11

5

11

0

-

195

0

-

85

75

-

165

12

5

4503001

11

0

-

265

190

-

345

80

-

235

160

-

315

12

5

4503002

260

-

615*

340

-

695

230

-

585*

310

-

665

12

5

4503003

610

-

1015*

690

-

1095

580

-

985*

660

-

1065

12

5

4503004

1000

-

1500*

1080

-

1580

970

-

1470*

1050

-

1550

12

10

4503005

1500

-

2000*

1580

-

2080

1470

-

1970*

1550

-

2050

12

10

4503006

2000

-

2500*

2080

-

2580

1970

-

2470*

2050

-

2550

12

10

4503007

2500

-

3000

2580

-

3080

2470

-

2970

2550

-

3050

12

10

4503008

3000

-

3500

3080

-

3580

2970

-

3470

3050

-

3550

12

10

4503009

3500

-

4000

3580

-

4080

3470

-

3970

3550

-

4050

12

10

4503010

4000

-

4500

4080

-

4580

3970

-

4470

4040

-

4550

12

10

450301

1

All dimensions are in mm

Содержание Multimar 844 T

Страница 1: ...Universal Gage 3722483 Mahr GmbH Standort Esslingen Reutlinger Str 48 73728 Esslingen Tel 49 711 9312 600 Fax 49 711 9312 756 mahr es mahr de www mahr com 1016 Multimar 844 T Operating Instructions ...

Страница 2: ...Important information Attention Danger Failure to follow instructions marked with these symbols can cause inaccurate results and lead to considerable damage to this product Introduction Intended working conditions The Universal Gage Multimar 844 T is a versatile precision measuring instrument which can be employed in both production and in inspection areas to measure the following External and int...

Страница 3: ...conjunction with the appropriate indicating instrument and accessories are subject to inspection equipment monitoring For this reason regular inspection equipment monitoring performed by either the user or Mahr Service must ensure compliance to the specified error limits Important hints prior to using the Multimar 844T The measuring instrument may only be used for its intended purpose For damages ...

Страница 4: ...ing force 6 3 Inserting exchanging the indicating instrument 7 4 Setting up the measuring arm holder 8 5 Setting with measuring standards e g setting ring combination of gage blocks master etc 9 6 Measurement 10 7 Technical Data 11 8 Accessories 12 9 Care and Maintenance 14 10 Spare Parts 15 ...

Страница 5: ...d protected against hand warmth 3 Symbols to identify the selected measuring direction Internal external measurement 4 Lifting lever 5 Stationary measuring arm holder adjustable 6 Moveable arm holder 7 Fixing screws for measuring arms 8 Clamping screw 9 Hex screw for adjusting the direction of the measuring force 10 Guide tube ...

Страница 6: ...t the Hex wrench into the bore hole hexagonal screw 3 Tighten the Hex screw hand tighten only From external to internal measurement 4 Insert the Hex wrench into the bore hole when the lifting lever is released 5 Loosen the Hex screw 6 Hold the lifting lever and push back per hand Due to the built in measuring force spring the moveable measuring arm can be moved very quickly this may cause damage t...

Страница 7: ...ing instrument in the indicating instrument holder 1 take into account the position of the measuring direction and align the appropriate readout position Tighten per hand the clamping screw on the indicating instrument holder 1 Please note The Protection bar 844 Tsb offers additional protection damage to the indicating instru ment see Chapter 8 Accessories ...

Страница 8: ...aptor 844 Tad this instrument is compatible with all the available measuring anvils with a M2 5 thread In order to always achieve reliable and accurate measuring results we recommend the use of the Depth stop 844 Tw Due to the exact positioning of the stops on the measuring arms it is possible to ensure pendular motion along a plane parallel Therefore accurate and continuously accurate measurement...

Страница 9: ... Enter the PRESET value of the indicating instrument corresponding to the measuring standard Position the Multimar 844 T on the measuring standard With light pendular motion determine the position of the reversal point Min and or Max value and here set the indicating instrument to the default PRESET value Please note To conduct absolute measurement a digital indicator with a dynamic measuring func...

Страница 10: ... T in to the position of measurement Release the lifter lever 4 so that the moveable measuring arm holder 6 so that there is contact on the work piece the constant measuring force is automatic Determine the reversal point Min and or Max value with pendular motion Read off the measuring result on the indicating instrument ...

Страница 11: ...ils 7 Technical Data Application range internal mm Application range internal extended mm Application range external mm Application range external extended mm Measuring range moveable probe mm Measuring force N Order no 30 115 110 195 0 85 75 165 12 5 4503001 110 265 190 345 80 235 160 315 12 5 4503002 260 615 340 695 230 585 310 665 12 5 4503003 610 1015 690 1095 580 985 660 1065 12 5 4503004 100...

Страница 12: ...e extended Measuring Arms 844 Te and Depth Stops 844 Tw In combination with Measuring anvils 844 Tp 844 Ts 844 Tk 844 Tr 844 Tg In combination with Adaptor 844 Tad and Measuring anvils 901 H 912 844 Te 844 Tad 901 H 902 H 903 H 904 H 906 H 907 908 H 911 H 912 844 Tp 844 Ts 844 Tk 844 Tr 844 Tg 844 Tw ...

Страница 13: ...a Measuring Arms 844 Tma and Depth Stops 844 Tw In combination with Measuring anvils 844 Ta 844 Tb 844 Tc 844 Td Measuring Arms 844 Tmi and Depth Stops 844 Tw In combination with Measuring anvils 844 Ti 844 Tb 844 Tc 844 Td 844 Tv 844 Tw 844 Tz 844 Ta 844 Ti 25 Eba ...

Страница 14: ...e heavy soiling with a cloth wetted with a neutral solvent Volatile organic solvents like thinners are not to be used as these liquids can damage the individual components Should you have any questions regarding the instrument contact us and we shall be pleased to answer them Measuring Arms 844 Ty In combination with Measuring Anvil 706 Vr and Holder 844 Tf Protection Bar 844 Tsb To protect the in...

Страница 15: ...screw M4x11 all 3 4503012 1 Protection bar all 4 4503116 E 1 Insulating handle 1 all 5 4879663 E 4 Hexagon socket screw M3x8 all 6 4503212 E 1 Milled screw M5x20 all 7 4503269 E 1 Insulating handle 2 4503001 4503002 8 4503117 E 1 Insulating handle 3 4503003 4503011 9 4503206 E 1 Lifting handle all 10 4503216 2 Storage rack all 10 Spare Parts ...

Страница 16: ...16 Mahr GmbH Multimar 844 T ...

Отзывы: