L A D E N M Ü H L E N
S H O P G R I N D E R
If the short circuit protection has
tripped, it has to be reset manually:
• Tilt the grinder slightly to the
left.
• Press the button (1) on the bot-
tom of the grinder and subse-
quently replace the machine in
its original position.
10.2 Faults
HINT
Ensure that customers using the equipment on a self-service basis are
advised to call service staff in the event of a fault. Customers must not
attempt to correct faults themselves by tampering with the machine.
We recommend placing a notice in the immediate vicinity of the ma-
chine as follows:
In the event of a fault please notify sales staff!
10.2.1 Fault correction
Fault
The grinder cannot
be switched on
Indication
The grinder is not con-
nected to the power
supply
The overload protection
/ Klixon has tripped
The overload protec-
tion / Klixon has tripped
again
The building fuse has
tripped
The cover plate has
not been replaced or
has been incorrectly
replaced
Corrective action
Check and, if necessary,
connect the mains plug
Switch on the Klixon.
Read section 10.1 “Pro-
tection devices”
Check whether any
foreign matter is blocking
the grinding disc. Pro-
ceed as described in sec-
tion 9.1.2 “Cleaning the
grinding mechanism”.
Subsequently switch on
the Klixon. Read section
10.1 “Protection devices”
Check and, if necessary,
switch on the fuse
Check and replace cor-
rectly
Содержание Tanzania
Страница 22: ...L A D E N M H L E N S H O P G R I N D E R 12 Electrical wiring diagram 200 230V 50Hz...
Страница 23: ...L A D E N M H L E N S H O P G R I N D E R 12 Electrical wiring diagram 100 115V 60Hz...
Страница 25: ...L A D E N M H L E N S H O P G R I N D E R Notes...
Страница 26: ...L A D E N M H L E N S H O P G R I N D E R Notes...
Страница 27: ...L A D E N M H L E N S H O P G R I N D E R Notes...