1.3
Safety regulations
1.3.1 BFX-20
Always carefully study and follow all the safety regulations before
using the MAHLE product. Correct use of the BFX-20 is impor-
tant for your personal safety and for trouble-free functionality.
Incorrect use can cause damage to the unit or lead to incorrect
functionality.
Brake fluids are poisonous and may cause damage
to health!
y
Regular maintenance should be performed on the BFX-20 to
ensure proper and safe operation.
y
Improper handling may lead to damage to health or property.
y
The brake maintenance device may only be operated by those
trained to use it. Unauthorized persons are not permitted to
operate it.
y
Always check the brake fluid exchange unit, hoses, cables and
plugs before use. Do not use the brake maintenance device if
it is damaged. The device may only be repaired by a specialist.
Never open the brake maintenance device yourself.
y
The BFX-20 unit should not be exposed to excess moisture
or be operated in wet areas.
y
Do not make any changes to the design of the brake fluid
exchange unit.
Pull out the plug before doing any work on the brake
fluid exchange unit. Plug in the plug only when the
brake fluid exchange unit is switched off.
y
Avoid any contact with brake fluid.
y
Wash skin immediately with water if it comes into contact
with brake fluid.
y
Remove contaminated clothes.
y
Do not carry any cleaning cloths or other items soaked in
brake fluid in your clothing.
y
Clean any spills immediately. Brake fluid is corrosive and will
damage the finish on most painted surfaces.
Wear suitable protective gloves to minimize the
danger of injury from contact with skin.
Wear protective goggles to minimize the danger of
injury from splashes.
y
Always use vehicle specified brake fluid. Failure to do so may
cause brake system damage. The unit is designed to use
DOT specified brake fluid. Use of any other fluid type is not
recommended and may void warranty.
y
It is important to test drive every vehicle after the service to
verify proper brake system operation. Failure to do so could
result in undetected brake system failure.
1.4
Technical data
Feature
Value/Range
Max. container size
5 Liters
Working pressure
0.4-3.5 bar
Main voltage
115 VAC / 60Hz
Filling hose length
3.5 m
Unit dimensions
290 x 310 x 400 mm
Weight
30 kg
Noise
≤70 dB(A)
Содержание BFX-20