32
BA492301-en
Pos: 134 /Produktfamilien/Alle Geräte/Überschriften/Überschriften 1.1/D/Überschrift 1.1: Display-Codes @ 20\mod_1270028830605_75.docx @ 832653 @ 2 @ 1
4.6
Display Codes
Pos: 135 /Produktfamilien/Hebetechnik/COLUMNLIFT/490801 RGE/BA/Inhalt: 4908 Display-Codes_12pt @ 26\mod_1325589138094_75.docx @ 1146073 @ @ 1
Display
Code
LED
Cause
Action
Green
Normal operation, no errors.
Normal operation.
See "Operating Modes;
Automatic Mode, Single Mode
and Group Mode in this manual.
Yellow
on 1 or
several
columns
Uncontrolled operation.
Bus line failure.
Replace connecting cable.
CAN bus without terminating
resistor.
Check terminating resistors of
CAN bus in dummy plug and
power supply unit, contact ser-
vice.
CAN controller out of step or
defective.
Turn the main switch off and on
again. If error persists, contact
service.
Controller in sleep mode due to
short-circuit of CAN lines.
Replace connecting cable. Con-
tact service if necessary.
Yellow
on 1 col-
umn,
Green on
all others
Safety switch triggered.
Carriage has made contact with
obstacle.
Switch column with error mes-
sage to single mode. Raise car-
riage to unlock the safety wedge
or remove obstacle.
Red on 1
column
Thermoswitch triggered.
Overheated motor. Lift stops and
error message appears.
Let the motor cool down. Check
thermoswitch, motor and col-
umn. Acknowledge error with
selector button on control panel.
Red LED will go out and the lift is
ready for operation.
Yellow
on all
columns
Insufficient speed / Overspeed.
Lift stops when irregular motor
speed is detected.
Release control element. The
error is removed and the lift is
ready for operation.