12
BA042501-en
Pos: 42 /Technische Dokumentation/Alle Geräte/Überschriften/Überschriften 1.1/B/Überschrift 1.1: Bedienung über EUROSYSTEM @ 34\mod_1382624285389_75.docx @ 1845679 @ 2 @ 1
3.2
Control via EUROSYSTEM
Pos: 43 /Technische Dokumentation/Alle Geräte/Überschriften/Überschriften 1.1.1/G/Überschrift 1.1.1: Gewichtssimulator @ 38\mod_1403791709436_75.docx @ 2045316 @ 3 @ 1
3.2.1
Weight Simulator
Pos: 44 /Technische Dokumentation/Bremsprüftechnik/MBT-SERIES/E10101 EUROSYSTEM Standard/BA/Inhalt: E101 Lastsimulation (MLS) @ 26\mod_1326872631372_75.docx @ 1511195 @ @ 1
When the Brake Test screen ap-
pears:
1 Open the Load Simulation screen
using <F6>.
2 Install the chains to the vehicle.
3 Enter the target weight.
The program will not accept any in-
puts greater than the maximum final
load which has been preset with the
key switch on the hydraulic power
unit.
When simulating loads of 12 / 14 / 20 t make sure to keep a minimum distance of
1 m between cylinders!
Load currently ap-
plied by the MLS
Current weight of
left-side wheel
Current weight of
right-side wheel
Current total axle weight
Target weight entered by user
LED indicating
preset maximum
final load