M A G U I R E   P R O D U C T S ,   I N C .  

 

 

17

M A G U I R E

 FLEXBUS™ 

Flexbus System Setup Options

 

 

 

The Setup screen also allows for setting:  Date and time, screensaver timeout, 
screen brightness, screen calibration, updating Flexbus controller and 
receiver/pump firmware, changing the password, language selection and date 
format.  To enter Setup press the Setup button on the home screen.  Default 
password is 22222. 

 

 

 

Set Date and Time 

Press the field you would like to edit.  Enter the current Date or Time by 
first pressing to select the field.   Press CE to clear the current date or time.  
Then enter the Date or Time as it would be displayed left to right.  Press 
the green check 

 when complete. 

 

 
 

Set Screensaver Timeout, Set Screen Brightness, Calibrate Screen 

Screen Saver is the elapsed time in minutes until an inactive (untouched) 
display will blank the screen and show the screen saver.  Setting the 
screen saver to 00 will disable the screen saver.  The Brightness slider 
allows the brightness of the screen to be adjusted.  Calibrate set the 
calibration of the touch screen's X-Y coordinates.  To complete, follow the 
prompts.  Press the green check 

 when complete. 

 

 
 

Update Flexbus Touchscreen Firmware 

Requires a firmware update provided by Maguire Products Inc.  Copy 
firmware to USB and insert USB into the controllers USB port.  Press this 
Update button.  Press the green check 

 to start the update.  The 

firmware update will be copied from the drive to the controller.  When the 
copy has completed, you will be prompted to turn toggle power (off/on).  
Update will be verified and applied on reboot of the controller. 

 

 
 

Update Receiver and Pump Firmware 

Requires a firmware update provided by Maguire Products Inc.  Copy 
firmware (.XUF file) to USB and insert USB into the controllers USB port.  
Press this Update button.  Press the green check 

 to start the update.  

The firmware update will be copied from the flash drive to the Pumps and 
Receivers that require the update (up-to-date firmware will not be 
changed).  When the copy has completed, you will be prompted to turn 
toggle power (off/on).  Updates to devices are logged in the Alarm/Event 
log. 

 

 

Change Passwords 

Set the Operator password and the Administrator password. 

 

Operator Password

 - When enabled, all Pump and Receiver 

parameter fields are password protected.  

 

Administrator Password

 - Changes the Administrator 

password. 

Содержание FLEXBUS

Страница 1: ...MAGUIRE PRODUCTS INC FLEXBUS FLEXBUS Lite FLEXBUS FLEXBUS Lite RECEIVER CONTROL SYSTEM INSTRUCTION MANUAL Original Instructions Manual Revision Date January 31 2020 Copyright Maguire Products Inc 2020...

Страница 2: ...M A G U I R E P R O D U C T S I N C 2 M A G U I R E FLEXBUS...

Страница 3: ...c accepts no responsibility or liability for damage or malfunction of the equipment arising from non observance of these operating instructions To avoid errors and to ensure trouble free operation it...

Страница 4: ...__________________ 11 Receiver Configuration ______________________________ 12 Pump Configuration _________________________________ 14 Removing Receivers or Pumps ________________________ 16 Flexbus S...

Страница 5: ...m loaders Easy Installation Install a single wire and conveniently located drops to connect the control to all receivers and pumps System Grows with Your Needs Each Flexbus central control allows addi...

Страница 6: ...rned on and discovered during the Pump Assignment routine and the Receiver Assignment routine setup processes Once the initial setup has been completed the Flexbus system will retain the setup and ide...

Страница 7: ...o enabled Flexbus Lite in the Maguire Weigh Scale Blender Press Display will prompt for a password default 22222 Then press Press System Configuration Display will show the System Configuration catego...

Страница 8: ...ssword is 22222 Press to confirm password This enters the Setup screen This screen contains several setup specific options Pumps and Receivers Setup Buttons Pressing PUMPS or RECEIVERS enters Setup fo...

Страница 9: ...of the screen This enters the PUMP assignment screen This gray screen contains any previously assigned pumps For first time setup this screen is probably blank and no pumps have been assigned At this...

Страница 10: ...S While in the Setup screen you can go straight to setting up Receivers without re entering the password PRESS To enter the Receivers assignment screen See Next Page for Receivers Assignment instructi...

Страница 11: ...then to be assigned Your receivers will appear on the screen and be numbered in the order that they were turned on If necessary pressing each receiver icon will allow you to re assign the ID number to...

Страница 12: ...reen using the arrow buttons and allows the receiver to be turned OFF or ON The receiver symbol can display the following states Pressing the Receiver symbol toggles receiver OFF or ON This symbol ind...

Страница 13: ...e valve will open to purge the convey line Purge time follows Load time Priority Sets the order of importance of the receivers Setting a receiver to level 1 sets to the highest priority while setting...

Страница 14: ...e pump navigation arrows at the bottom center of this screen Pump Overview Screen Pump Configuration Screen Pump Navigation Pump Navigation and Status Panel This multi function panel displays messages...

Страница 15: ...lt Time Interval is 5 1 400ms IDLE TIME The time in minutes that the pump runs after the last convey request before shutting off BYPASS The time delay in 10ths of seconds 0 50 zero seconds to 5 second...

Страница 16: ...st be turned off or communication must be disconnected to remove the device When a device is turned off or communication to the device is disconnected the loader or pump icon will show a red X over it...

Страница 17: ...ordinates To complete follow the prompts Press the green check when complete Update Flexbus Touchscreen Firmware Requires a firmware update provided by Maguire Products Inc Copy firmware to USB and in...

Страница 18: ...the green check when complete Pump Alarm Setup Enables or disables pump Filter Alarm and pump Motor Failure Alarm Filter Alarm On power up system detects if filter is present During pump operation sys...

Страница 19: ...Setup Enters password protected setup screens Receivers Navigation Setup of all Receivers Pumps Navigation Setup of all Pumps Live Status Panel In the Live Status Panel the receivers will display the...

Страница 20: ...r s power is off or a disconnected communication wire Receiver is inactive Receiver is alarming Virgin material filling receiver Regrind material filling receiver Regrind Layering Proportional Loading...

Страница 21: ...d Alarm Log Each event or alarm will have the date and time the receiver or pump ID number involved in the alarm or log and the reason for the alarm or log Alarms and logs are listed with the most rec...

Страница 22: ...M A G U I R E P R O D U C T S I N C 22 M A G U I R E FLEXBUS Flexbus Wiring Diagrams...

Страница 23: ...M A G U I R E P R O D U C T S I N C 23 M A G U I R E FLEXBUS...

Страница 24: ...M A G U I R E P R O D U C T S I N C 24 M A G U I R E FLEXBUS Flexbus Component Map...

Страница 25: ...M A G U I R E P R O D U C T S I N C 25 M A G U I R E FLEXBUS Flexbus Lite Component Map...

Страница 26: ...M A G U I R E P R O D U C T S I N C 26 M A G U I R E FLEXBUS...

Страница 27: ...M A G U I R E P R O D U C T S I N C 27 M A G U I R E FLEXBUS...

Страница 28: ...d and of all other obligations or liabilities on our part and MAGUIRE PRODUCTS neither assumes nor authorizes any other persons to assume for it any other liability in connection with the sale of its...

Страница 29: ...459 4300 Fax 610 459 2700 Email info maguire com Web www maguire com Maguire Europe Tame Park Tamworth Staffordshire B775DY UK Tel 44 1827 265 850 Fax 44 1827 265 855 Email info maguire europe com Mag...

Отзывы: