Magtrol 3410 Скачать руководство пользователя страница 1

Model 3410

Torque Display

User’s Manual

Содержание 3410

Страница 1: ...Model 3410 Torque Display User s Manual...

Страница 2: ...prohibited TRADEMARKS LabVIEW is a trademark of National Instruments Corporation National Instruments is a trademark of National Instruments Corporation Windows is a registered trademark of Microsoft...

Страница 3: ...Torque Transducers and electronic products are earth grounded to ensure personal safety and proper operation 2 Make sure that torque transducers and motors under test are equipped with appropriate sa...

Страница 4: ...re updated 6 3 6 3 1 6 3 2 6 3 3 09 21 10 Preliminary manual rev F TF models 205 and 209 added 5 2 2 1 05 14 10 Preliminary manual rev E TF models 205 and 209 added 4 1 2 02 10 09 Preliminary manual r...

Страница 5: ...ANEL INPUTS AND OUTPUTS 5 2 2 2 REAR PANEL CONTROLS AND BUTTONS 6 3 INSTALLATION CONFIGURATION 7 3 1 POWERING UP THE 3410 7 3 1 1 LINE VOLTAGE 7 3 1 2 SELF TEST 7 3 1 3 MAIN MENU 8 4 MANUALLY CONTROLL...

Страница 6: ...CALIBRATION PROCESS 18 6 3 1 INITIAL CALIBRATION PROCEDURE 18 6 3 2 TORQUE OFFSET AND GAIN 18 6 3 3 FREQUENCY GAIN 19 7 TROUBLESHOOTING 20 APPENDIX A SCHEMATICS 21 A 1 78P205 BOARD 21 GLOSSARY 22 IND...

Страница 7: ...y 8 Figure 3 3 Revision Display 8 Figure 3 4 Main Menu 8 4 MANUALLY CONTROLLED OPERATION Figure 4 1 System Display 9 Figure 4 2 Device Setup Menu 9 Figure 4 3 Saving System Display 9 Figure 4 4 Model...

Страница 8: ...teration The structure of the manual is as follows Chapter 1 INTRODUCTION Contains the technical data sheet for the 3410TorqueTransducer Display which describes the unit and provides its mechanical an...

Страница 9: ...This is used to draw the operator s attention to information directives procedures etc which if ignored may result in damage being caused to the material being used The associated text describes the...

Страница 10: ...ansducer and utilizes high speed digital signal processing to display torque speed and mechanical power Its features include High Quality Easy to Read Display Vacuum fluorescent readout Isolated RS 23...

Страница 11: ...rocessing DSP to display torque speed and mechanical power It includes a tare function to help offset any slight residuals caused by couplings or suspended loads The 3410 may also be used with sensors...

Страница 12: ...lange Torque Transducer Connector Cable 10 m ER 116 02 TF Flange Torque Transducer Connector Cable 20m ER 116 03 Displays Torque Speed and Mechanical Power Values RS 232C Connection Isolated RS 232 In...

Страница 13: ...ns and torque transduce MODEL 3410 TORQUE DISPLAY POWER TORQUE SPEED Figure 2 1 Front Panel The displays from left to right are POWER TORQUE SPEED Overload Indicator If the inputs exceed the range of...

Страница 14: ...connectors and receptacles for connecting to appropriate equipment along with a power switch and 3 control buttons RS 232C 16VA 50 60Hz 85 264VAC INPUT FUSE 500 mA 250V T 5 20mm MAGTROL TRANSDUCER SY...

Страница 15: ...o Use Function POWER Press I to turn power ON Press O to turn power OFF Turns power ON or OFF SYSTEM Press Enables setup of torque measuring device transducer model torque units power units and displa...

Страница 16: ...e case of the 3410 is earth grounded 3 1 1 Line Voltage The 3410 will operate with either of the following power sources without any modifications 120 V 50 60 Hz 240 V 50 60 Hz 3 1 2 Self Test Note To...

Страница 17: ...POWER TORQUE SPEED Figure 3 2 Title Display Then an additional display will appear indicating the version of your Magtrol 3410 Torque Displa POWER TORQUE SPEED Figure 3 3 Revision Display 3 1 3 Main M...

Страница 18: ...EM button once The System Display will flash momentarily POWER TORQUE SPEED Figure 4 1 System Display Then the Device Setup Menu will appear POWER TORQUE SPEED Figure 4 2 Device Setup Menu 2 Press and...

Страница 19: ...HS 309 TMB 309 TF 209 TM HS 210 TMB 210 TM HS 310 TMB 310 TF 210 TM HS 211 TMB 211 TM HS 311 TMB 311 TF 211 TM HS 212 TMB 212 TM HS 312 TMB 312 TF 212 TM HS 213 TMB 213 TM HS 313 TMB 313 TF 213 TM HS...

Страница 20: ...of measure is displayed 3 Press and release SYSTEM button 3 times The Saving System Display will flash momentarily and the unit will automatically return to the Main Menu 4 1 4 Power Units Setup Selec...

Страница 21: ...n until desired brightness is reached select from a range of 1 to 3 3 Press and release SYSTEM button once The Saving System Display will flash momentarily and the unit will automatically return to th...

Страница 22: ...is activated the software will turn on an NPN transistor internal to the 3410 that is in an open collector configuration This output or collector is found on pin 12 of the 14 pin connector on the back...

Страница 23: ...3 RX 8 2 TX 4 7 1 4 3 2 5 6 9 8 7 Figure 5 1 RS 232 Interface 5 1 1 Connection The RS 232 connection includes null modem wiring internal to the unit To install use a straight through pin to pin connec...

Страница 24: ...return data string with this format SxxxxxTxxxxxRcrlf or SxxxxxTxxxxxLcrlf R or L is the shaft direction indicator as viewed looking at the dynamometer shaft where R right clockwise CW L left counter...

Страница 25: ...ets encoder units to when device SPECIAL UD5 1 to 6000 Programmed value is not saved at power down UI Selects model For measurments to be accurate the correct transducer model must be specified Note R...

Страница 26: ...212 TMB 212 TM HS 311 TM HS 309 TMB 311 TF 216 N A 9 TM HS 213 TMB 213 TM HS 312 TM HS 310 TMB 312 TF 217 N A 10 TM HS 214 N A TM HS 313 TM HS 311 TMB 313 TF 218 N A 11 TM HS 215 N A TM HS 314 TM HS 3...

Страница 27: ...med in the following order 1 Initial Procedure 2 Torque Offset and Gain computer 3 Frequency Gain Note this is available on Software revision L1 forward Items needed for calibrating the 3410 External...

Страница 28: ...your meter reading 8 The response will be CAL COMPLETE 6 3 3 Frequency Gain 1 Send the command CALS to the unit via the serial port 2 The response will be FREQ XXXXXX XX 3 Apply a square wave of 50 k...

Страница 29: ...t of instructions Use correct command and format Mechanical power reads much higher or lower than expected Torque units or scale factor is incorrect Set torque input units and scale factor to match th...

Страница 30: ...I V I D M T 1 2 A 7 U 4 1 C H 4 7 Q E R F Q E R F B P D E T I B B P D E T I B 1 1 R K 8 9 6 9 R K 8 9 6 5 6 C 7 U 4 1 C H 4 7 3 4 B 7 U 4 1 C H 4 7 E V I R D E T I B T U 0 V 5 4 2 R K 0 1 5 2 R K 0 1...

Страница 31: ...panel controls PC personal computer remote computer control uses programmed controls from personal computer rpm revolutions per minute RS 232 Recommended Standard 232C a standard interface approved by...

Страница 32: ...Outputs L Line Voltage 7 M Main Menu 8 Menus Contrast Setup 12 Main 8 Power Units Setup 11 Torque Units Setup 11 Model Selection 10 O Offset Torque 18 Outputs 5 See also Inputs Speed 5 Torque 5 P Para...

Страница 33: ...ment a quotation listing all the necessary parts and labor costs if any will be faxed or e mailed to you 6 After receiving your repair estimate provide Magtrol with a P O number as soon as possible A...

Страница 34: ...ardenville Parkway Buffalo New York 14224 USA Phone 1 716 668 5555 Fax 1 716 668 8705 E mail magtrol magtrol com MAGTROL SA Route de Montena 77 1728 Rossens Fribourg Switzerland Phone 41 0 26 407 3000...