MagneSafe V5
118
[P35] [Encrypted Session ID]
[P35] [DUKPT serial number/counter]
[P35] [Clear Text CRC]
[P35] [Encrypted CRC]
[P35] [Format Code]
[P34]
Each of the Pxx elements has the default value in this configuration, thus we
can reinterpret the format as:
%[Tk1 Masked Data]?
;[Tk2 Masked Data]?
+[Tk3 Masked Data]?
|[Reader Encryption Status]
|[Tk1 Encrypted Data (including TK1 SS and ES)]
|[Tk2 Encrypted Data (including TK2 SS and ES)]
|[Tk3 Encrypted Data (including TK3 SS and ES)]
|[MagnePrint Status]
|[Encrypted MagnePrint data]
|[Device serial number]
|[Encrypted Session ID]
|[DUKPT serial number/counter]
|[Clear Text CRC]
|[Encrypted CRC]
|[Format Code]
<ENTER>
Using this information, we can put the respective data from the Raw Data into
the structure:
%B5452000000007189^HOGAN/PAUL ^08040000000000000000000?
;5452000000007189=080400000000000000?
+5163000050000445=000000000000?
|0600
|C25C1D1197D31CAA87285D59A892047426D9182EC11353C051ADD6D0F072A6CB3436560B3071FC1FD11D9F7
E74886742D9BEE0CFD1EA1064C213BB55278B2F12
|724C5DB7D6F901C7F0FEAE7908801093B3DBFE51CCF6D483E789D7D2C007D539499BAADCC8D16CA2
|E31234A91059A0FBFE627954EE21868AEE3979540B67FCC40F61CECA54152D1E
|A1050000
|8628E664C59BBAA232BA90BFB3E6B41D6F4B691E633C311CBE6EE7466B81196EC07B12648DCAC4FD7FD0E21
2B479C60BAD8C74F82F327667
|
|21685F158B5C6BE0
|FFFF9876543210E00008
|B78F
|
|0000
Note: The Device Serial Number field is empty because the DSN has not been set.
Note: The Encrypted CRC field is empty because the default configuration
is to send it empty.
Note that at Security Level 3 the following fields are represented as
ASCII characters:
Masked Track data
Format Code