SAFETY 

This product has been evaluated by multiple safety certification agencies, including 
Underwriters Laboratories (UL) and the United States Federal Communications 
Commission (FCC Class A and Class B), and is designed to protect both the user and the 
device.  This document is written specifically to work in conjunction with these safety and 
integrity features to protect the user and the device.  It is very important to follow all steps 
in the product documentation carefully, in the order in which they are described, and at 
the recommended times.  Failure to do so could result in personal injury, and / or cause 
damage to the device, and / or void the product warranty.

 

 
The information within this manual has been prepared for use by trained professional 
service personnel and is not intended for general use.  To maintain the safety and integrity 
of the machine, follow the procedures described in this manual carefully. 
 
For your personal safety and to prevent damage to the device, disconnect power from the 
device before you connect or disconnect any cable, electronic board, or assembly. 

 

SAFETY REQUIREMENTS 

 Caution: Never do any of the following:  

 

DO NOT use a ground adapter plug to connect equipment to a power socket-outlet that lacks a ground 
connection terminal. 

 

DO NOT attempt any maintenance function that is not specifically described in this manual or in 
other ExpressCard 2000 instructional documents published by MagTek. 

 

DO NOT override or “cheat” electrical or mechanical interlock devices. 

 

DO NOT use EC2000 supplies or cleaning materials for other than their intended purposes. 

 

DO NOT operate the equipment if you or anyone else have noticed unusual noises or odors. 

 

Consider the following before operating the ExpressCard 2000: 

 

Connect the EC2000 to a properly grounded AC power socket-outlet.  If in doubt, have the socket-
outlet checked by a qualified electrician.  Improper connection of the device’s grounding conductor 
creates a risk of electric shock. 

 

Place the EC2000 on a solid surface that can safely support the device’s weight support the weight of 
the EC2000 PLUS the weight of a person leaning against the device (such as a service technician). 

 

Be careful when moving or relocating the device.  Use proper lifting techniques. 

 

Use materials and supplies specifically designed for MagTek devices.  Using unsuitable materials 
may result in poor performance, and in some cases may be hazardous. 

 
 

Содержание ExpressCard 2000

Страница 1: ...one 562 546 6400 I Technical Support 888 624 8350 www magtek com ExpressCard 2000 Instant Issuance Card Personalization System XY Transport Ribbon Cable Replacement Procedure September 22 2014 Manual...

Страница 2: ...may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of MagTek Inc MagTek is a registered trademark of MagTek In...

Страница 3: ...ect any cable electronic board or assembly SAFETY REQUIREMENTS Caution Never do any of the following DO NOT use a ground adapter plug to connect equipment to a power socket outlet that lacks a ground...

Страница 4: ...tents Table of Contents 4 1 Required Tools Materials and Documents 5 1 1 Required Tools 5 1 2 Suggested Tools 5 1 3 Required Materials 5 1 4 Suggested Materials 5 1 5 Required Software and Documents 5...

Страница 5: ...1 ea Flashlight 1 3 Required Materials Part Number Quantity Description 33070992 1 ea ASM REPLACEMENT KIT XY CABLE EC2000 1 4 Suggested Materials Part Number Quantity Description 33011009 1 ea ASM KI...

Страница 6: ...r and maintenance functions so many of the cross references to deeper how to procedures from that manual have been removed for brevity The information in this document is intended for use by trained p...

Страница 7: ...sensitive consumables from the device including card stock image printer ribbons indent cartridges and tipper foils Some consumables contain negative imprints of cardholder data and must be handled se...

Страница 8: ...stalling the entire XY transport module see 99875607 ExpressCard 2000 Hardware Service Manual or 33070932 ExpressCard 2000 XY Transport Module Replacement Procedure Figure 3 1 XY Transport Showing Rib...

Страница 9: ...ut Board TOP VIEW 3 On the rear side of the XY transport locate the two retaining clips that secure the ribbon cable to the transport Lift both clips firmly toward the ceiling to unlock and eject the...

Страница 10: ...nce Card Personalization System XY Transport Ribbon Cable Replacement Procedure Page 10 5 Disconnect the ribbon cable from the breakout board on the top deck plate and set the cable aside 6 If there i...

Страница 11: ...p deck plate with the cable coming off the board toward the front of the device Press down to make sure the connection is solid Figure 3 4 Breakout Board Connection of XY Transport Ribbon Cable TOP VI...

Страница 12: ...nsport End of Ribbon Cable TOP VIEW FROM LEFT 4 Connect the cable to the XY transport as shown in Figure 3 7 It should come off the XY transport toward the front of the device before looping back towa...

Страница 13: ...ribbon cable should wind and unwind in a straight line it should not twist bend diagonally or move to the side b The ribbon cable should not contact any objects in its path c If the ribbon cable touc...

Отзывы: