Appendix E - EMV Factory Defaults (EMV Only)
eDynamo| Secure Card Reader Authenticator | Programmer’s Manual (COMMANDS)
Page 226 of 245 (
D998200115-17
)
Tag
Default Value (Hex)
Max.
Length
Configurable
Tag Description
DFDF05
9A 82 9F 36 9F 1E 9F
10 9F 5B 9F 33 9F 35
95 9F 01 5F 24 5A 5F
34 8A 9F 15 9F 16 9F
39 9F 1A 9F 1C 57 9F
02 5F 2A 9F 21 9C
0x80
MagTek
Reversal message for EMV
transaction
DFDF06
8A 91
0x02
MagTek
Tags participating in online response
DFDF16
00 00 00 80
0x04
MagTek
Maximum length of issuer script
(Read Only)
DFDF17
9A DF DF 28 9F 02 9F
03 5A 89 9F 10 9F 15
9F 16 9F 4E 82 8E 5F
24 5F 25 9F 06 9F 07
9F 0D 9F 0E 9F 0F 9F
26 9F 27 9C 9F 33 9F
34 9F 35 9F 36 9F 37
9F 39 9F 40 9F 41 9F
53 95 9B 9F 5B DF DF
00 9F 1E 9F 1A 5F 2A
9F 01 8A DF 81 20 DF
81 21 DF 81 22 5F 20
5F 34 9F 09 84
0x80
MagTek
EMV Transaction Result Message
Tags