3 - Mechanical Integration
Dynamag Duo| Secure Card Reader Authenticator | Installation and Operation Manual
Page 12 of 23 (
D998200203-10
)
3
Mechanical Integration
The device is designed to be mounted to a fixed surface. Consider the following when planning and
designing the mechanical aspects of the solution:
From device delivery through assembly, shipping, installation, usage, and maintenance, the device
must not be exposed to conditions outside the ratings in
Appendix A Technical Specifications
If the device is exposed to cold temperatures, adjust it to warmer temperatures gradually to avoid
condensation, which can interfere with the operation of the device or cause permanent damage.
The device does not contain any user-serviceable parts. Disassembling or modifying the device will
void the manufacturer warranty.
Solution training should direct assemblers, operators, and maintenance personnel to use a clean, dry
cloth to clean the device. Do not use chemicals or solvents.
Overall dimensions of the device are shown in
Figure 3-1 - Dynamag Duo Mechanical Dimensions in Inches [mm]
The device can be oriented either horizontally or vertically.
The device must be positioned on a flat, accessible surface with at least 4 inches clearance on either
end for room to swipe a card.
The mount surface must have a hole to that can accommodate the device’s USB cable, and must be
large enough for the USB connector to fit through during installation / replacement.
The device incorporates drain holes, shown in
. Drainage requirements are as follows:
o
The drain holes must not be obstructed.
o
The device must be oriented with the drain holes on the bottom.
The device is designed to be mounted using mounting tape or
M3.5
size screws through the mount
provides detailed dimensions of mounting screw hole locations and sizes. The
mounting screw holes are not connected to the electrical system and needn’t be grounded.