DIGITRAC

%%%%

 2 Specifications

Supply Voltage

115 or 230 volts rms, 

10%

Supply Frequency:

50 or 60 cycles per second, sinusoidal

Fuses: F1, F2

1.6 amp, Littelfuse Part No. 21601.6, or

Wickmann Part No. 19194-053-FS

Enclosure

D2

Front Panel

IP65   (IEC529)

Enclosure

IP20   (IEC529)

D2E

IP65   (IEC529)

Climatic Class:

3K3 (EN60721)

Temperature Range:

Operating

0

-

C to 40

-

C

Storage

-30

-

C to +80

-

C

Relative Humidity

5% to 85%

Pollution Degree:

2 (IEC664-1)

Altitude:

0 to 2000 m

Compatible Residual 

Current Devise Types:

A or B (IEC755)

Worst Case Fault Current:

1.6 amp

Inputs:

Tension Sensor

2.1 mvdc using +5 and -5 vdc (10 vdc)

across one 350 ohm sensor or two 350 ohm sensors 

in parallel, or

100 mvdc, using 5 volts across one 100 ohm full bridge,

or

0 to +10 vdc analog

Diameter

0 to +10 vdc analog, or

20 to 10,000 pulses per second, 5 volt TTL

Web Speed

0 to +10 volts analog, or

20 to 10,000 pulses per second, 5 volt TTL

E-Stop

switch closure or 5 vdc or 24 vdc logic

Run/Stop

switch closure or 5 vdc or 24 vdc logic

Tension Off

switch closure or 5 vdc or 24 vdc logic

Format

switch closure or 5 vdc or 24 vdct logic

Outputs:

Torque

0 to +10 vdc., 1 madc maximum

4 to 20 madc, 500 ohms maximum

-10 to +10 vdc, 1 madc maximum

Tension Reference

0 to +5 vdc., 1 madc maximum

20

Содержание DIGITRAC 2

Страница 1: ...6 4 Setup and Calibration 3 3 PA 2 Installation 17 5 PA 2 PA 90 Installation 5 4 Wiring Diagrams 18 6 Optional Features 6 5 Outline Dimensions 19 7 Trouble Shooting 12 6 Screen Flow Chart 21 8 Reset P...

Страница 2: ...f IP65 over its front panel It also meets the environmental and mechanical requirements of EN50178 The D2 mounting clips found on both sides of the enclosure behind the front panel will accommodate pa...

Страница 3: ...Route AC power away from sensor and control wiring MAGPOWR sensor cables are color coded on the nameplate Run all wiring in shielded cable Connect shields to the enclosure using the standoffs provided...

Страница 4: ...Then continue through the flow chart at right entering the desired data in each screen 4 2 Tension Sensor Calibration NOTE Continuing beyond this point will erase any previous sensor calibration in th...

Страница 5: ...g power to the control Remove the D2 cover or open the D2E door Set JP6 on the D2 p c board to 0 10V and voltage Set JP1 on the power amplifier for the desired output current range On Model D2 unplug...

Страница 6: ...ers JP11 and JP12 Connect wires to TB2 and TB3 as shown using shielded wiring Only one full bridge can be used 10 vdc TENSION SIGNAL On main PCB cut jumpers JP10 JP11 JP12 and JP13 Connect signal betw...

Страница 7: ...function During STOP TIME the DIGITRAC 2 continues to control tension as a closed loop system but INERTIA COMP and STOP MULTIPLIER are also activated See Section 6 7 to use isolated logic inputs 5 to...

Страница 8: ...cted per Section 6 1 6 8 OPERATOR SCREENS The operator screens are those normally used during machine operation and are accessed using NEXT ITEM or PRIOR ITEM from the HOME screen These are the only s...

Страница 9: ...on to calculate the inertia and required stopping torque as the roll diameter changes If a diameter input is not used the DIGITRAC 2 estimates diameter More accurate results are obtained if a diameter...

Страница 10: ...is used CORE TENSION 18 This is the DESIRED TENSION at CORE DIAMETER when taper tension is used MANUAL LEVEL 48 The output set point percent when in MANUAL mode OUTPUT LEVEL Current output as a perce...

Страница 11: ...PING automatic mode after the stop signal is received At the end of this time the control goes to HOLD mode Stop time should be slightly longer than actual machine stopping time PROGRAM CONFIGURE SCRE...

Страница 12: ...OFF on the keypad once If REMOTE TENSION ON OFF is set to LEVEL one or more of the remote tension off switches are closed E STOP is active except unwind E STOP is wired incorrectly JP8 7 not set for...

Страница 13: ...ed rating of both i e 100 lbs for two 50 lbs sensors Calculate this load from LOAD 2 MAX SIN WRAP 2 where MAX maximum tension entered during sensor calibration WRAP wrap angle Tension oscillates DIAGN...

Страница 14: ...ON ON OFF does not work DIGITRAC 2 configured for LEVEL for external TENSION ON OFF When LEVEL is selected for TENSION ON OFF only external tension on off can be used E STOP is active E STOP is wired...

Страница 15: ...am reset is complete The basic tension sensor calibration is still in memory but dynamic calibration must be reprogrammed or C 1 Turn the power to the DIGITRAC 2 OFF for 5 seconds 2 Press SHIFT and 3...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...lt Current 1 6 amp Inputs Tension Sensor 2 1 mvdc using 5 and 5 vdc 10 vdc across one 350 ohm sensor or two 350 ohm sensors in parallel or 100 mvdc using 5 volts across one 100 ohm full bridge or 0 to...

Страница 21: ......

Страница 22: ......

Отзывы: