![Magnum Original Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/magnum/original-series/original-series_use-and-installation-manual_3674306010.webp)
Use and installation manual for a MAGNUM sauna stove
16.06.2015 10
Starsauna Oy
Technical support:
Pistotie 4
15860 Hollola, Finland
III.Installation of the sauna stove
The electrical installation may only be performed by a qualified
electrician.
Instructions for electrical installation are provided in the circuit
diagram in these installation directions and on a sticker in the
sauna stove.
The electrical installation work may only be performed by an
electrician qualified for the job in accordance with applicable
regulations.
The sauna stove is connected to the power grid semi-permanently with
H07RN-F or similar rubber cable.
Check the required cable dimensions in the table below.
Note: the use of a PVC cable as a connection cable is not allowed.
The power switch in the device is a so-called control switch and does not
fully de-energize the sauna stove.
Table
Sauna stove
POWER
FUSE
FEED CABLE
SIZE OF THE
SAUNA
Magnum 6.6
6.6 KW
3x10 A
5x1.5 mm2
5-9 m3
Magnum 9
9 KW
3x16 A
5x2.5 mm2
8-15 m3
Magnum 10.5
10.5 KW
3x16 A
5x2.5 mm2
10-20 m3