Use and installation manual for a MAGNUM sauna stove  

16.06.2015  18 

Starsauna Oy 

 

Technical support: 

 

Pistotie 4 

 

[email protected] 

15860 Hollola, Finland 

 

4.3 

Piling stones in the sauna stove

 

Preparations 
1. Ensure that the control panel, the temperature sensor, any floor heating reduction and the sauna 
stove have been correctly connected to the power supply 
by an electrician. 
 
2. The benches should be installed before the stones are 
piled in the sauna stove, 

IF 

the sauna stove is integrated 

through the benches. It will be difficult to move the sauna 
stove after the stones have been piled it. Place the sauna 
stove in its intended location, considering the safety 
distances. 
 
3. For piling stones in the sauna stove, you will need a 
spirit level, protective gloves, 80 – 110 kg of washed rocks with a diameter of 5 – 10 cm, depending 
on the sauna stove model (check the correct amount from the manual), and the resistors that were 
included in the sauna stove delivery. 
 
 
Piling stones 

 
1. Straighten the sauna stove with the help of a spirit level. The 
spirit level can be lowered between the resistors to the lower 
level of the sauna stove, where you can check the straightness. 
Check the straightness in both directions, adjust with the 
adjustment feet. If no stones have been piled into the sauna 
stove yet, the adjustment feet can be rotated by hand, but they 
can also be adjusted with a 17 mm ring spanner. 
 

2. Pile the stones into the lower part of the sauna stoves. Do 
not wedge the resistors. Ensure that the resistors travel 
vertically where they have been attached to the bottom plate, 
throughout the entire section where the stones have been 
installed. Stop piling stones when you reach the end of the 
middle part of the resistor, and move to Section 3.

 

ENSURE throughout the entire stone piling process that 
there are stones between the resistors, and that the 
resistors cannot come in contact with each other! If the 

stones have been piled incorrectly, the resistors can melt 
into each other, which is not covered by the warranty!

 

 
3. Lower the resistor plate onto the stones as shown on the 
images, and continue piling the stones. It is very important to 
pile stones properly between the resistors, and for the resistors 
to be aligned straight. This ensures that the resistors cannot 
bend against each other, which might otherwise cause the 
resistors to break. However, do not put too many stones 

between the resistors.  
 
 

Содержание Original Series

Страница 1: ...Original Sauna Stove 6 6 kW 9 0 kW 10 5 kW MAGNUM Cenik and Lite Sauna Stove 6 6 kW 9 0 kW 10 5 kW Magnum Ruutu L and C 6 6kW 9 0kW 10 5kW Use and Installation With Finlandia and Magnum RC Control Ce...

Страница 2: ...ature 7 2 3 Heating time 7 2 4 Timer 8 2 5 Turning the sauna on 8 2 6 Directions for using the sauna 9 3 Installation of the sauna stove 10 3 1 Installation 11 3 2 Installing the thermostat sensor 13...

Страница 3: ...instructions for setting up and using the sauna stove after the stove has been installed Malfunctions caused by errors in installation or use are not covered by the warranty THIS INCLUDES ERRORS IN T...

Страница 4: ...immediately 2 Menu button By pressing this you can move through the menus of the device as follows Default mode Target temperature Heating time Timer Default mode 3 button This button is used to decr...

Страница 5: ...sauna immediately 2 Menu button By pressing this you can move through the menus of the device as follows Default mode Target temperature Heating time Timer Default mode 3 button This button is used to...

Страница 6: ...other using the Menu button When the sauna stove is on the and buttons may be used to move to the mode where you can adjust the settings in the order shown in the image above 1 4 Menu structure Magnum...

Страница 7: ...na temperature is on the display pressing the or button causes the controller to move directly to setting the target temperature Leaving this menu is done as in section 1 Section II 3 Heating time You...

Страница 8: ...heating the sauna until the target temperature has been reached The stove s indicator light in the controller will be turned on The decimal mark lights up on the lower right side of the screen as a si...

Страница 9: ...a and the ventilation Use water that is suitable for domestic use when throwing water on the stove for heating the sauna Do not throw water on the stove if there are people next to it as the water spl...

Страница 10: ...llation work may only be performed by an electrician qualified for the job in accordance with applicable regulations The sauna stove is connected to the power grid semi permanently with H07RN F or sim...

Страница 11: ...In the Lite Cenik model turn the sauna stove on its side against a clean platform Make sure the sauna stove is not scratched 4 Open the hatch at the base of the sauna stove and connect the feeder line...

Страница 12: ...e the stones have been installed 13 Install the stainless steel frame of the upper part of the sauna stove Chapter 4 3 image 3 14 Pile the stones in the upper part of the sauna stove in a way that ens...

Страница 13: ...or and press it carefully all the way down When installing the thermostat sensor on the wall the distance from the roof to the upper edge of the sensor should be 100 mm The sensor must be located 500...

Страница 14: ...ctor card to the sauna stove is the same for the Finlandia and Magnum RC models Connecting the Finlandia controller card Connecting from the left The Control panel can be installed inside the sauna In...

Страница 15: ...ve as set in Chapter 3 3 NOTE The electric grid connection process may only be performed by a licensed electrician The bottom of the box is not delivered with the sauna stove One suitable box is the A...

Страница 16: ...sauna stove is 500 1000 mm PAY ATTENTION TO THE INCOMING AIR VALVE If incoming air cannot be directed away from the thermostat the valve may not be installed less than 1000 mm from the incoming air v...

Страница 17: ...AGNUM sauna stove 16 06 2015 17 Starsauna Oy Technical support Pistotie 4 info magnumkiuas fi 15860 Hollola Finland 4 2 Ventilation in the sauna room Power ventilation for the sauna and the electric s...

Страница 18: ...level of the sauna stove where you can check the straightness Check the straightness in both directions adjust with the adjustment feet If no stones have been piled into the sauna stove yet the adjus...

Страница 19: ...ling stones in the sauna stove Ensure that there are enough stones on top It is recommended to choose big stones for the top of the sauna stove so that they cannot fall through the vertical profiles 7...

Страница 20: ...in Ruutu sauna stoves anywhere between the squares 2 Bend the brackets if necessary PLEASE NOTE if you are bending the brackets by hand use protective gloves 3 When the bracket seems to be positioned...

Страница 21: ...Number of stones approx 80 kg approx 80 kg approx 100 kg Lite 6 6 Lite 9 0 Lite 10 5 kW Power 6 6 KW 9 KW 10 5 KW Diameter of the lower part 320 mm 320 mm 320 mm Diameter of the upper part 320 360 mm...

Страница 22: ...60 mm Fuse 3x10A 3x16A Connection Cable 5x1 5 mm2 5x2 5 mm2 Stone Amount n 120kg n 120kg 5 2 Safety distances Minimum safety distances MAGNUM ORIGINAL MODELS Sauna stove 700 mm to the lower bench Over...

Страница 23: ...6 6 kW and 9 kW 360 mm 100 mm Tulip 6 6 kW and 9 kW 360 mm 100 mm Pillar 6 6 kW 9 kW and 10 5 kW 320 mm 125 mm Reed 10 5 kW 360 mm 100 mm Vase 10 5 kW 370 mm 100 mm Tulip 10 5 kW 370 mm 100 mm CENIK u...

Страница 24: ...nual for a MAGNUM sauna stove 16 06 2015 24 Starsauna Oy Technical support Pistotie 4 info magnumkiuas fi 15860 Hollola Finland 5 3 Images showing the safety distances The distances are always measure...

Страница 25: ...on during the warranty period The manufacturer may charge for possible spare parts if a warranty term has been breached When troubleshooting for issues outside the scope of the manual the buyer should...

Страница 26: ...Use and installation manual for a MAGNUM sauna stove 16 06 2015 26 Starsauna Oy Technical support Pistotie 4 info magnumkiuas fi 15860 Hollola Finland 7 Connection diagram...

Страница 27: ...such as when the sensor s short circuit has been removed or an overheated device has cooled down sufficiently After this you may attempt to turn the device on again Error code symptom Legend ER1 There...

Отзывы: