16
CANPLUS DISPLAY
Soft buttons simplify the user interface by displaying a button bar
above the buttons when any of the first four buttons
(buttons 1 to 4, starting from the left) are pressed. Icons on the button bar change to represent the current function
of each button. The button bar disappears after five seconds if no further buttons are pressed.
Note:
Different software versions may have slightly different displays.
ANALOG GAUGE PAGES
Analog Gauge Pages
provide four independent pages of analog gauges. To enable Analog Gauge Pages, press any
of the first four buttons to show the top level button bar and then press button 1
. Alternate pages are selected
by repeated pressing of button 1. The four standard analog gauge pages are shown below.
Note:
Engine hours are displayed as a digital value even on Analog Gauge Pages. The default analog gauge pages
represent 13 selections since the tachometer is repeated in the upper right quadrant of each page.
All 16 gauges may be configured by the user to create an application-specific view of CANbus data. Gauges on the
current page can be changed via Adjust mode,
accessed by pressing button 5
when the button bar is visible.
Gauges can be changed on any of the four pages by selecting the page to be changed and then entering Adjust mode
.
Note:
“Quad Adjust” must me enabled to access the Adjust mode.
In Adjust mode,
a new button bar is displayed identifying the button functions. Button 1
corresponds to the
upper left gauge, button 2
to the upper right gauge, button 3
to the bottom left gauge and button 4
to the bottom right gauge. Successive presses of the buttons selects a different parameter for the gauge. Adjust
mode
is exited by pressing button 5
and storing the new configuration even when power is removed.
Note:
A gauge selection can only appear once per page. To move a gauge selection, the existing gauge location
must be changed first. Gauge selections are limited to the data currently being received. Analog gauge pages can
be configured in Demo mode to select any supported parameter. Refer to Data Parameters Monitored for a complete
list of available parameters.
Adjust mode
can be disabled in the “Configuration” menu (“Quad Adjust - Off”)
to prevent accidental changes.
Page 1
Page 2
Page 3
Page 4