CONTROL PANEL COMPONENTS
A.
ENGINE START SWITCH:
This switch must be in the ON position to start the engine. To stop the engine,
place switch in OFF position.
B.
AUTO IDLE SWITCH:
When this switch is engaged, the engine speed will return to idle whenever the
generator is not under load.
C.
ENGINE START:
Push button for electric engine starting option.
D.
VOLTAGE SWITCH:
This switch changes voltage on the L14-30R outlet from 120V to 240V.
E.
MAIN CIRCUIT BREAKER:
This unit contains a 25A circuit breaker.
F.
GFCI TEST MODULE:
This module is the ground fault circuit interrupter to protect all electrical outlets.
G.
120/240V TWIST-LOCK CONVENIENCE OUTLET:
This L14-30R outlet is used to connect additional loads or
equipment to the generator.
H.
120V TWIST-LOCK CONVENIENCE OUTLET:
This L5-30R outlet is used to connect additional loads or
equipment to the generator.
I.
DUPLEX OUTLET BREAKERS:
Two 20A push-button circuit breakers are supplied for the 120V duplex
convenience outlets.
J.
120V DUPLEX CONVENIENCE OUTLETS:
These 120V outlets are used to connect additional loads or
equipment to the generator.
9
GROUND FAULT
SENSING MODULE
WARNING
TEST BEFORE EACH USE
SEE INSTRUCTIONS
RESET
RESET