WARNING!  

 
Smoke and gases! 
Smoke and gases can lead to breathing difficulties and poisoning. In addition, solvent 
vapour (chlorinated hydrocarbon) may be converted into poisonous phosgene due to 
the ultraviolet radiation of the arc! 

• 

Ensure that there is sufficient fresh air! 

• 

Keep solvent vapour away from the arc beam field! 

• 

Wear suitable breathing apparatus if appropriate! 

 
Fire hazard! 
Flames may arise as a result of the high temperatures, stray sparks, glowing-hot parts 
and hot slag produced during the welding process. 
Stray welding currents can also result in flames forming! 

• 

Check for fire hazards in the working area! 

• 

Do not carry any easily flammable objects such as matches or lighters. 

• 

Keep appropriate fire extinguishing equipment to hand in the working area! 

• 

Thoroughly remove any residue of flammable substances from the workpiece before 

starting welding. 

• 

Only continue work on welded workpieces once they have cooled down. 

Do not allow to come into contact with flammable material! 

• 

Connect welding leads correctly! 

 
Risk of accidents if these safety instructions are not observed! 
Non-observance of these safety instructions is potentially fatal! 

• 

Carefully read the safety information in this manual! 

• 

Observe the accident prevention regulations in your country. 

• 

Inform persons in the working area that they must observe the regulations! 

 
Danger when coupling multiple power sources

Coupling multiple power sources in parallel or in series has to be carried out by 
qualified personnel and in accordance with the manufacturer's guidelines. Before 
bringing the power sources into service for arc welding operations, a test has to verify 
that they cannot exceed the maximumallowed open circuit voltage. 

• 

Connection of the machine may be carried out by qualified personnel only! 

• 

When decommissioning individual power sources, all mains and welding current leads have 

to be safely disconnected from the welding system as a whole. (Danger due to inverse 
voltages

!

• 

Do not couple welding machines with pole reversing switch (PWS series) or machines for 

AC welding, as a minor error in operation can cause the welding voltages to be combined. 
 

 

WARNING!  

 
Hazards due to improper usage! 
Hazards may arise for persons, animals and material objects if the equipment is not 
used correctly. No liability is accepted for any damages arising from improper usage! 

• 

The equipment must only be used in line with proper usage and by trained or expert staff! 

• 

Do not modify or convert the equipment improperly! 

 

 

 
 

 

 

Содержание MIG 190 II DIGITAL

Страница 1: ...MAGNUM MIG 190 II DIGITAL INSTRUCTIONS MANUAL WARNING FOR SAFETY REASON PLEASE READ AND UNDERSTAND THE FOLLOWING INSTRUCTIONS BEFORE FIRST USE OF THE DEVICE ...

Страница 2: ... persons as a result For this reason we do not accept any responsibility or liability for losses damages or costs arising from incorrect installation improper operation or incorrect usage and maintenance or any actions connected to this in any way Read the operating instructions for all system components Observe accident prevention regulations Observe all local regulations Confirm with a signature...

Страница 3: ...Even low voltages can cause you to get a shock and lead to accidents Do not touch any live parts in or on the machine Connection cables and leads must be free of faults Switching off alone is not sufficient Place welding torch and stick electrode holder on an insulated surface The unit should only be opened by specialist staff after the mains plug has been unplugged Only wear dry protective clothi...

Страница 4: ...ntially fatal Carefully read the safety information in this manual Observe the accident prevention regulations in your country Inform persons in the working area that they must observe the regulations Danger when coupling multiple power sources Coupling multiple power sources in parallel or in series has to be carried out by qualified personnel and in accordance with the manufacturer s guidelines ...

Страница 5: ...anteed at all times Equipment damage due to dirt accumulation Unusually high quantities of dust acid corrosive gases or substances may damage the equipment Avoid high volumes of smoke vapour oil vapour and grinding dust Avoid ambient air containing salt sea air Non permissible ambient conditions Insufficient ventilation results in a reduction in performance and equipment damage Observe the ambient...

Страница 6: ...ion 3 1 Front view 1 Overheat Mulfunction indicator light 2 Power ON indicator light 3 Welding process selector switch MMA MIG TIG 4 Wire feed button 5 Welding current regulation knob MMA 6 Polarization selector plug 7 Cable connector 8 Mig torch EURO connector 9 Wire feed speed regulation knob 10 Welding voltage regulation knob for MIG 11 Burnbuck function regulation knob 12 Welding voltage displ...

Страница 7: ...e sure that all the rollers installed in the drive assembly are corresponding to the type and diameter of the wire inserted Factory installed rolls are intended for steel wire from 0 6 to 0 8mm For steel wires use V shaped groove rolls and for aluminium wires U shaped groove rolls Place the wire spool on the spool mount taking care to ensure that the wire unwinding direction was in line with the d...

Страница 8: ...ge or slower wire feed can also result in more spatter and large droplets developing at the tip You can reduce that by increasing the voltage value or wire feed speed 9 MIG MAG welding tips Welding horizontal butt joints of thin materials should be carried out using push technique However for thick material it should be a pull technique For vertical butt joints of thin elements place the joint fro...

Страница 9: ... surface 3 Use a wire diameter and spool weight according to the table 4 Check the technical condition of the device and welding cables 5 Remove any flammable materials from the welding area 6 Use suitable protective clothing for welding gloves apron safety boots and welding helmet 12 Troubleshooting Symptoms Possible cause Remedy Wire feed does not feed the wire or feeding is irregular feeder mot...

Страница 10: ...rce of danger 15 Warranty The manufacturer of the device provides full warranty service for the power supply unit within 24 months from the day device was purchased An individual warranty card is issued for each device Warranty is valid only if all conditions listed in the instructions manual were fulfilled If the device was used inappropriate or against instructions the warranty becomes invalid S...

Отзывы: