Magnum CSW412 Скачать руководство пользователя страница 3

ii 

© 

2015 Sensata Technologies

IMPORTANT PRODUCT SAFETY INSTRUCTIONS

This manual contains safety instructions that must be followed during the 

installation and operation of this product. Read all instructions and safety 

information on the inverter and in this manual before installing or using.

Safety Symbols

To reduce the risk of electrical shock, 

fi

 re, or other safety hazard, the 

following safety symbols have been placed throughout this manual to 

indicate dangerous situations and important safety instructions.

WARNING:

 Indicates that failure to take a speci

fi

 ed action could 

result in physical harm to the user.

CAUTION:

 Indicates that failure to take a speci

fi

 ed action could result 

in damage to the equipment.

Info:

 Indicates information that emphasizes or supplements important 

points of the main text.

Product Safety Warnings

WARNINGS: 

Failure to follow the instructions below and in this 

manual can result in death or serious injury.

• 

All electrical work must be performed in accordance with local, state and 

federal electric codes.

•  This product is designed for indoor/compartment installation. Do not 

expose to rain, snow, moisture, or liquids of any type.

• 

Use insulated tools to reduce the chance of electrical shock or accidental 

short circuits. Be sure to remove all jewelry such as rings, watches, 

bracelets, etc., when installing or performing maintenance on the inverter.

• 

Always disconnect the batteries or energy source prior to installing or 

performing maintenance on the inverter. Live power may be present at 

more than one point since an inverter utilizes both batteries and AC.

• 

Do not cover or obstruct any air vent openings and/or install in a zero-

clearance compartment - always operate unit in an open area.

•  When working with electrical equipment or lead acid batteries, have 

someone nearby in case of an emergency.

• 

Study and follow all the battery manufacturer’s speci

fi

 c precautions when 

installing, using, and servicing the battery connected to the inverter.

• 

While working with batteries, wear eye protection and gloves, and avoid 

touching your eyes. Keep fresh water and soap on hand in the event battery 

acid comes in contact with eyes. If this occurs, cleanse right away with soap 

and water for a minimum of 15 minutes and seek medical attention.

• 

Batteries produce explosive gases, DO NOT smoke or have an open spark 

or 

fi

 re near the system.

• 

Avoid dropping any metal tool or object on the battery. Doing so could 

create a spark or short circuit which goes through the battery or another 

electrical tool and may cause an explosion.

• 

Shock Hazard! Keep away from children!

• 

These inverters provide household AC, treat the AC output sockets the 

same as regular wall AC sockets at home.

• 

Explosion hazard! DO NOT use this inverter in the vicinity of 

fl

 ammable 

fumes or gases (such as propane tanks or large engines).

•  These inverters contain no user-serviceable parts. See the Warranty 

section for how to handle service issues.

Содержание CSW412

Страница 1: ...Owner s Manual CSW Series Pure Sine Wave Inverter...

Страница 2: ...s Restrictions on Use The CSW Series inverter may only be used in life support devices or systems with the express written approval of Sensata Technologies Failure of the CSW Series inverter can reaso...

Страница 3: ...the inverter Always disconnect the batteries or energy source prior to installing or performing maintenance on the inverter Live power may be present at more than one point since an inverter utilizes...

Страница 4: ...2 3 2 Torque Requirements 11 2 4 DC Wiring 12 2 4 1 DC Wire Sizing 13 2 4 2 DC Overcurrent Protection 14 2 4 3 DC Grounding 14 2 4 4 DC Cable Connections 14 2 4 5 Wiring the Battery Bank 15 2 4 6 Appl...

Страница 5: ...Mounting Positions 9 Figure 2 4 CSW412 Dimensions 9 Figure 2 5 CSW1012 Dimensions 10 Figure 2 6 CSW2012 Dimensions 10 Figure 2 7 DC Cable to Battery Terminals 17 Figure 2 8 DC Cable to Inverter s DC...

Страница 6: ...nit with a model specific prefix Note Enter your inverter s serial number in the table at the bottom of page i It is to easier to record this information now instead of trying to gather it after the u...

Страница 7: ...shelf wall 10 DC Negative Terminal black the inverter s connection to the negative terminal on the 12 VDC battery bank 11 DC Positive Terminal red the inverter s connection to the positive terminal o...

Страница 8: ...USB Port allows USB enabled devices to be powered and charged 4 ON OFF Power Switch a 2 position switch that turns the inverter on and off 5 Serial Number the unique identification number assigned to...

Страница 9: ...ry compliance information 12 DC Positive Terminal red the inverter s connection to the positive terminal on the 12 VDC battery bank 1 3 Regulatory Compliance The CSW Series inverters are intended to b...

Страница 10: ...should not be the determining factor as to whether the installation is compliant that is the responsibility of the electrician and the onsite inspector 2 1 1 Installation Guidelines Before connecting...

Страница 11: ...S15 Transfer Switch CSW Series Inverter AC Loads 15A max DVD Tools TV AC Sub Panel AC Outlet DC Disconnect Fuse Battery Bank DC Ground Vehicle chassis DC ground bus or engine negative bus AC Main Pane...

Страница 12: ...e pass thru mode the conductor from the transfer switch to the dedicated load will be protected as long as the branch rated circuit breaker at the AC source does not exceed the ampacity of the conduc...

Страница 13: ...like gasoline or propane or in locations that require ignition protected devices Close to the battery bank As with any inverter it should be located as close to the batteries as possible Long DC wires...

Страница 14: ...allation Mount flat on a horizontal surface only For Indoor Use Flat on a horizontal surface right side up or upside down DC terminals to the right left or the top Note The CSW inverter cannot be moun...

Страница 15: ...on Figure 2 5 CSW1012 Dimensions Figure 2 6 CSW2012 Dimensions Top 10 3 26 2 cm 6 3 16 1 cm 6 9 17 5 cm 12 6 32 1 cm Front AC Side Back DC Side 3 4 8 4 cm Top 13 4 34 cm 8 5 21 6 cm 9 1 23 cm 16 5 41...

Страница 16: ...ng must cross AC or vice versa try to make the wires at the crossing point perpendicular 90 degrees to one another DC overcurrent protection must be provided as part of the installation Use only coppe...

Страница 17: ...e chance of radio frequency interference Be aware that over tightening or misthreading the nuts on the DC terminals can cause the bolts to strip and snap break off Make sure cables have a smooth bend...

Страница 18: ...ppropriate overcurrent protection may be used if the inverter will only be connected to a dedicated load as shown in Figure 2 2 and the inverter and dedicated load have been thoroughly tested and sold...

Страница 19: ...he metallic chassis of the various enclosures together to have them at the same voltage potential to reduce the possibility for electric shock For most installations the inverter chassis and the negat...

Страница 20: ...able Also allow at least 1 2 5 cm of space between the batteries to provide good air flow DO NOT mount the batteries directly under the inverter CAUTION Install batteries in a well ventilated area Bat...

Страница 21: ...bles to the inverter DC terminals a brief spark or arc may occur this is normal and due to the inverter s internal capacitors being charged 3 Route and connect an appropriately sized DC positive wire...

Страница 22: ...al M6 1 0 hex nut CAUTION Ensure nothing is placed between the DC terminal and the ring lug CSW1012 Inverter lock washer 12 flat washer BATTERY DC cable with ring lug bolt flat washer nut lock washer...

Страница 23: ...ctions to the inverter and batteries have been completed plug a small AC load e g 40W light bulb or small appliance into the GFCI s outlet and follow these steps to test the installation and the inver...

Страница 24: ...to turn the unit off WARNING The Power ON OFF Switch is not a power disconnect switch and will not remove the DC power from the inverter Disconnect all power to the inverter before working on the unit...

Страница 25: ...the unit has shut down Check the error code on the digital display When the status indicator lights amber or red use the digital display and the troubleshooting tables in Section 4 0 to resolve the is...

Страница 26: ...he battery is fully charged If the cables are sized correctly the connections are good and the battery is charged you may need a larger battery bank see Loads turning on and off Loads turning off and...

Страница 27: ...before restarting Check if the air flow is being blocked E05 Unit has sensed the input voltage is low and has initiated a warning alarm 11 2 VDC Recharge the battery to at least 11 8 VDC as the unit w...

Страница 28: ...w Voltage Recovery 12 0 VDC 11 8 VDC High Voltage Shutdown3 15 75 VDC 15 5 VDC Output Power Warning NA Yes with warning code Output Power Shutdown Yes Yes with shutdown code Output Power Shutdown Yes...

Страница 29: ...Sensata in Everett WA After the completion of service under this limited warranty Sensata will return the product prepaid to the original purchaser via a Sensata selected non expedited surface freight...

Страница 30: ...PN 64 0063 Rev C Magnum Dimensions Products Manufactured by Sensata Technologies 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www Magnum Dimensions com...