4.0 Troubleshooting

4.0 Troubleshooting

Use Table 4-1 to troubleshoot your inverter. For CSW1012 or CSW2012 

inverters, also use Table 4-2 to view the unit’s digital display to determine 

what condition triggered the error/warning code and what corrective action 

is needed.

Table 4-1, Troubleshooting Guide

Code

Condition

Corrective Action

E01

Unit has sensed the input 

voltage is low (<10.5 VDC) and 

will shut down in 30 seconds.

Immediately recharge the 

battery (to at least 11.8 VDC), 

and then restart unit.

E02

Unit has sensed the input 

voltage is high and has shut 

down.

Check the battery voltage, or if 

an external charger is connected 

to the battery bank.

E03

Unit output has sensed an 

overload or short circuit and 

was shut down.

Check the load connected to 

the output. Reduce the load 

and restart the unit.

E04

Unit has sensed the internal 

temperature was high and has 

shut down.

Turn the unit off and wait 15 

minutes before restarting. 

Check if the air 

fl

 ow is being 

blocked.

E05

Unit has sensed the input 

voltage is low and has initiated 

a warning alarm (@11.2 VDC).

Recharge the battery (to at 

least 11.8 VDC) as the unit will 

shut down shortly.

E06

Unit has sensed that the 

connected load is close to the 

overload shutdown limit.

Reduce the connected load.

E07

Unit has sensed the internal 

temperature is high and is close 

to the thermal shutdown limit.

Reduce the load and check if 

any of the unit’s ventilation is 

blocked.

Problem

Symptom

Solution

No AC output. Status 

indicator is off.

The unit is off.

Turn on the unit. See Operation 

instructions.

No power to 

inverter.

Check if fuse or disconnect 

switch (if installed) is either 

blown or turned off.

No AC output. Status 

indicator is green.

GFCI was 

tripped.

Check the connected load and 

reset the GFCI.

No AC output. Fault 

indicator is on.

Unit has 

detected a fault 

and has shut 

down. 

Determine and resolve the 

fault condition (e.g., high or 

low voltage, load too large, or 

over-temperature).

For CSW1012 

and CSW2012: 

Check error code on the display 

and use Table 4-2 to correct.

Table 4-2, CSW1012 and CSW2012 Inverter Error Codes

Содержание CSW412

Страница 1: ...Owner s Manual CSW Series Pure Sine Wave Inverter...

Страница 2: ...s Restrictions on Use The CSW Series inverter may only be used in life support devices or systems with the express written approval of Sensata Technologies Failure of the CSW Series inverter can reaso...

Страница 3: ...the inverter Always disconnect the batteries or energy source prior to installing or performing maintenance on the inverter Live power may be present at more than one point since an inverter utilizes...

Страница 4: ...2 3 2 Torque Requirements 11 2 4 DC Wiring 12 2 4 1 DC Wire Sizing 13 2 4 2 DC Overcurrent Protection 14 2 4 3 DC Grounding 14 2 4 4 DC Cable Connections 14 2 4 5 Wiring the Battery Bank 15 2 4 6 Appl...

Страница 5: ...Mounting Positions 9 Figure 2 4 CSW412 Dimensions 9 Figure 2 5 CSW1012 Dimensions 10 Figure 2 6 CSW2012 Dimensions 10 Figure 2 7 DC Cable to Battery Terminals 17 Figure 2 8 DC Cable to Inverter s DC...

Страница 6: ...nit with a model specific prefix Note Enter your inverter s serial number in the table at the bottom of page i It is to easier to record this information now instead of trying to gather it after the u...

Страница 7: ...shelf wall 10 DC Negative Terminal black the inverter s connection to the negative terminal on the 12 VDC battery bank 11 DC Positive Terminal red the inverter s connection to the positive terminal o...

Страница 8: ...USB Port allows USB enabled devices to be powered and charged 4 ON OFF Power Switch a 2 position switch that turns the inverter on and off 5 Serial Number the unique identification number assigned to...

Страница 9: ...ry compliance information 12 DC Positive Terminal red the inverter s connection to the positive terminal on the 12 VDC battery bank 1 3 Regulatory Compliance The CSW Series inverters are intended to b...

Страница 10: ...should not be the determining factor as to whether the installation is compliant that is the responsibility of the electrician and the onsite inspector 2 1 1 Installation Guidelines Before connecting...

Страница 11: ...S15 Transfer Switch CSW Series Inverter AC Loads 15A max DVD Tools TV AC Sub Panel AC Outlet DC Disconnect Fuse Battery Bank DC Ground Vehicle chassis DC ground bus or engine negative bus AC Main Pane...

Страница 12: ...e pass thru mode the conductor from the transfer switch to the dedicated load will be protected as long as the branch rated circuit breaker at the AC source does not exceed the ampacity of the conduc...

Страница 13: ...like gasoline or propane or in locations that require ignition protected devices Close to the battery bank As with any inverter it should be located as close to the batteries as possible Long DC wires...

Страница 14: ...allation Mount flat on a horizontal surface only For Indoor Use Flat on a horizontal surface right side up or upside down DC terminals to the right left or the top Note The CSW inverter cannot be moun...

Страница 15: ...on Figure 2 5 CSW1012 Dimensions Figure 2 6 CSW2012 Dimensions Top 10 3 26 2 cm 6 3 16 1 cm 6 9 17 5 cm 12 6 32 1 cm Front AC Side Back DC Side 3 4 8 4 cm Top 13 4 34 cm 8 5 21 6 cm 9 1 23 cm 16 5 41...

Страница 16: ...ng must cross AC or vice versa try to make the wires at the crossing point perpendicular 90 degrees to one another DC overcurrent protection must be provided as part of the installation Use only coppe...

Страница 17: ...e chance of radio frequency interference Be aware that over tightening or misthreading the nuts on the DC terminals can cause the bolts to strip and snap break off Make sure cables have a smooth bend...

Страница 18: ...ppropriate overcurrent protection may be used if the inverter will only be connected to a dedicated load as shown in Figure 2 2 and the inverter and dedicated load have been thoroughly tested and sold...

Страница 19: ...he metallic chassis of the various enclosures together to have them at the same voltage potential to reduce the possibility for electric shock For most installations the inverter chassis and the negat...

Страница 20: ...able Also allow at least 1 2 5 cm of space between the batteries to provide good air flow DO NOT mount the batteries directly under the inverter CAUTION Install batteries in a well ventilated area Bat...

Страница 21: ...bles to the inverter DC terminals a brief spark or arc may occur this is normal and due to the inverter s internal capacitors being charged 3 Route and connect an appropriately sized DC positive wire...

Страница 22: ...al M6 1 0 hex nut CAUTION Ensure nothing is placed between the DC terminal and the ring lug CSW1012 Inverter lock washer 12 flat washer BATTERY DC cable with ring lug bolt flat washer nut lock washer...

Страница 23: ...ctions to the inverter and batteries have been completed plug a small AC load e g 40W light bulb or small appliance into the GFCI s outlet and follow these steps to test the installation and the inver...

Страница 24: ...to turn the unit off WARNING The Power ON OFF Switch is not a power disconnect switch and will not remove the DC power from the inverter Disconnect all power to the inverter before working on the unit...

Страница 25: ...the unit has shut down Check the error code on the digital display When the status indicator lights amber or red use the digital display and the troubleshooting tables in Section 4 0 to resolve the is...

Страница 26: ...he battery is fully charged If the cables are sized correctly the connections are good and the battery is charged you may need a larger battery bank see Loads turning on and off Loads turning off and...

Страница 27: ...before restarting Check if the air flow is being blocked E05 Unit has sensed the input voltage is low and has initiated a warning alarm 11 2 VDC Recharge the battery to at least 11 8 VDC as the unit w...

Страница 28: ...w Voltage Recovery 12 0 VDC 11 8 VDC High Voltage Shutdown3 15 75 VDC 15 5 VDC Output Power Warning NA Yes with warning code Output Power Shutdown Yes Yes with shutdown code Output Power Shutdown Yes...

Страница 29: ...Sensata in Everett WA After the completion of service under this limited warranty Sensata will return the product prepaid to the original purchaser via a Sensata selected non expedited surface freight...

Страница 30: ...PN 64 0063 Rev C Magnum Dimensions Products Manufactured by Sensata Technologies 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www Magnum Dimensions com...

Отзывы: