7
26D4750
MCUF Series Vent-Free Firebox
FIREBOx LOCATION and CLEARANCE REqUIREMENTS
LOCATION OF FIREBOx
Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
•
Clearance to side wall, ceiling, woodwork and windows.
Refer to “Clearances/Height Requirements on Page 8.
Minimum clearances to combustibles
must be main-
tained.
•
Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.
•
Installation must provide adequate ventilation and com-
bustion air.
•
Location should be out of high traffic or windy or drafty
areas.
•
DO NOT INSTALL WHERE CURTAINS, FURNITURE,
CLOTHING OR OTHER FLAMMABLE OBJECTS ARE
LESS THAN 42" FROM FRONT OF HEATER.
•
Never obstruct the front opening of the vent-free firebox
or restrict the flow of combustion and ventilation air.
•
Minimize modifications to existing construction. Refer
to Figure 3 below for location suggestions.
•
Do not install in the vicinity where gasoline or other
flammable liquids may be stored. The vent-free firebox
must be kept clear and free from these combustible
materials.
FP2440
fireplace locations
Figure 3 -
Possible Firebox Locations
MINIMUM CLEARANCES
Ensure that minimum clearances shown in Figures 4
through 7 are maintained. Left and right clearances are
determined when facing the front of the firebox.
Follow these instructions carefully to ensure safe instal-
lation. Failure to follow these requirements may create a
fire hazard.
1.
Sidewall clearances:
The clearance from the inside
of the appliance to any combustible wall should not be
less than 6".
Figure 4
2.
Ceiling clearance:
The ceiling must be at least 42”
from the top of the firebox opening.
Figure 4
3.
Back wall clearance:
The appliance may be placed
against a combustible back wall.
6"
Minim
um
42"
Minim
um
6"
Minim
um
FP2687
minimum clearances
FP2687
Figure 4 -
Clearance and Height Requirements
4. Floor clearance:
This inner chamber firebox floor must
be installed at least 6" above any combustible flooring
material, such as carpeting or asphalt tile, which is
closer than 14" to the base of the firebox.
Figure 5
Or
The inner chamber firebox floor may be installed nearer
to the floor if a minimum of 14" of noncombustible mate-
rial such as slate or marble is installed between the base
of the firebox and the combustible flooring.
Figure 6