MCUF Series Vent-Free Firebox

GAS LINE INSTALLATION

W

ARNING

plumbing  connections  should  only  be 

performed by a qualified, licensed plumber. 

Main gas supply must be off when plumbing 

gas line to fireplace or performing service.

W

ARNING

W

ARNING

Connecting  directly  to  an  unregulated 

propane  /  L.p.G.  tank  can  cause  an 

explosion.

Do not connect directly to natural gas 1/2 

pSI or 2 pSI systems. Always make sure 

natural gas pressure is regulated 10.5 w.c. 

(maximum before operating the unit). 

Consult all local codes. All gas piping must be installed to 

comply with local codes, or in the absence of local codes, 

with the latest edition of the National Fuel Gas Code ANSI 

Z223.1/NFPA54.
Remove  the  baseplate  for  ease  of  gas  line  installation. 

Remove three (3) screws along the front edge of the base-

plate. Remove four (4) screws which secure the baseplate 

to the combustion casing (two at rear and one along each 

side). Replace baseplate prior to connecting gas line to 

heater. Consult heater installation and operating instruc-

tions for correct installation of the heater into the firebox.
The 1/2" gas line may enter either from the left side or right 

side of the firebox. Gas access holes are provided on both 

sides of the firebox.
A listed manual shutoff valve must be installed upstream 

of the appliance. A union tee and plugged 

1

/8" NPT pres-

sure  tapping  point  should  be  installed  upstream  of  hte 

appliance.

IMpORTANT:

 Install main gas valve (equipment shutoff 

valve) in an accessible location. The main gas valve is for 

turning on or shutting off the gas to the fireplace.
A sediment trap may be upstream of the heater to prevent 

moisture and contaminants from passing through trap to 

the heater controls and burners. Failure to do so could 

prevent the heater from operating reliably. Consult appli-

cable codes.
An external regulator must be used on all propane / L.P.G. 

heaters, in addition to the regulator fitted to the heater, to 

reduce the supply tank pressure to 13" w.c. (maximum). 

Any copper tubing used to supply propane / L.P.G. from 

the tank must be internally tinned. 

NOTE:  When  connecting  propane  /  L.p.G.  vent-free 

room heaters, you must use pipe sealant resistant to 

propane / L.p.G.
IMpORTANT: Hold heater regulator with a wrench to 

prevent movement when connecting to inlet piping.
Check gas type: The gas supply must be the same as 

stated on the heater’s rating plate. If the gas supply 

is different, DO NOT INSTALL THE HEATER. Contact 

your dealer for the correct model.

After completing connection, test all gas joints from the 

gas  meter  to  the  gas  heater  regulator  for  leaks.  Using 

soap and water solution or a gas sniffer. DO NOT USE 

AN OPEN FLAME.

Содержание 36MCUFD-R

Страница 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier For use with a listed gas fired unvented decorative room heater not to exceed 40 000 BTU hr Do Not Build a Wood Fire Carefully review the instr...

Страница 2: ... Installation 10 Canopy Installation 11 Combustion Air 12 Optional Equipment 15 Brass or Chrome Trim 15 Optional Wide Canopy 15 Forced Air Kit 15 Replacement Parts 16 Warranty 19 PLEASE READ THE INSTALLATION OPERATING INSTRUCTIONS BEFORE USING APPLIANCE Thank you and congratulations on your purchase of a Majestic Vent Free firebox IMPORTANT Read all instructions and warnings carefully before start...

Страница 3: ...ater in a bathroom or bedroom 12 Correct installation of the logs proper location of the heater and annual cleaning are necessary to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on surfaces outside the fireplace See log placement instructions for proper installation 13 Avoid any drafts that alter burner flame patterns Do not allow fans ...

Страница 4: ...er provisions for combustion air are provided the screen shall have an opening s for induction of combustion air 26 Do not fill spaces around the firebox with insulation or other materials These spaces must be maintained to prevent the firebox from coming in contact with com bustible materials Nous recommandons que nos appareils de chauffage au gaz soient installés et entretenus par des profession...

Страница 5: ...ING SUPPLIES Phillips screwdriver Square Framing materials Hammer Saw and or sabersaw Tee joint Level Pipe wrench Measuring tape Pliers Electric drill and bits Fireplace surround materials noncombustible Caulking material noncombustible Piping complying with local codes Wall finishing materials Pipe sealant approved for use with propane L P G resistant to sulfur compounds Refer to the installation...

Страница 6: ...K J J L 37 6M I Ref 36MCUF 42MCUF A 41Z v 47 B 36 42 C 18Z v 18Z v D 32 38 E 20C v 20C v F 27Z v 33Z v G 33M 39M H 41Z v 47Z v I 17C v 17C v J 48C v 53 K 68M 74M L 34Z x 37Z x Figure 1 Firebox and Framing Dimensions A B C D E FP2686 hearth dims Ref 36MCUFE F 36MCUFD R 42MCUFE F 42MCUFD R A 26Z v 25C v 32Z v 31C v B 15 14C v 15 14C v C 32B 31Z 38B 38Z D 25 25 25 25 E 20Z x 20Z x 20Z x 20Z x Figure ...

Страница 7: ... The vent free firebox must be kept clear and free from these combustible materials FP2440 fireplace locations Figure 3 Possible Firebox Locations MINIMUM CLEARANCES Ensure that minimum clearances shown in Figures 4 through 7 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instructions carefully to ensure safe instal lation Failure to follo...

Страница 8: ... the clearance requirements as shown in Figure 7a However if lower mantel height is desired refer to Figure 7b NOTE The Vermont Castings Group Barrington Cabinet Mantel Model series BWC300 BWC400 and BWC500 are specially designed to comply with all mantel temperature requirements Any custom built mantel must comply with all clearance requirements shown in this instruction manual 12 10 8 6 256O 12 ...

Страница 9: ...r materials This could cause a fire 1 Bend out the nailing flanges located on each side of the firebox 2 Slide the firebox into prepared framing or position firebox in its final position and frame later 3 Level the firebox by checking the top edge of the firebox Shim if necessary 4 Anchor firebox to the side framing members using 8d nails or other suitable fasteners Figure 9 5 The canopy must be i...

Страница 10: ... firebox A listed manual shutoff valve must be installed upstream of the appliance A union tee and plugged 1 8 NPT pres sure tapping point should be installed upstream of hte appliance IMPORTANT Install main gas valve equipment shutoff valve in an accessible location The main gas valve is for turning on or shutting off the gas to the fireplace A sediment trap may be upstream of the heater to preve...

Страница 11: ...Figure 11 2 Align the canopy with the holes in the top frame 3 Replace the screws previously removed 4 Tighten side screws Make sure the canopy is level and secure WARNING The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater WARNING Close fireplace screen panel before operating a decorative type unvented room heater FP2695 ...

Страница 12: ... or garage space 5 Locate air supply inlet at least 3 away from any ap pliance vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly These conditions increase the resistance to the free flow of air through the duct Refer to Figures 12 through 15 for methods of installing the outside air for combustion assemblies FP2843 OA...

Страница 13: ...clamp or screws Figure 17 WARNING DO NOT remove the cover if the outside air will not be connected FP1900 OA start collar 8 08 Figure 16 Attach Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Insulation Ring AK 4 Starting Collar Sheet Meal Screws Left Side of Fireplace Shorter End of Air Starting Collar FP2700 OA duct Screws Air Starting Collar Duct Left Side of Fireplace...

Страница 14: ... the wall NOTE If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Install model 403 duct connector 1 Push insulation back approximately 2 from the end of each duct 2 Slip each duct over duct connector until an equal length of connector extends into each duct 3 Place duct clamp over the end of ...

Страница 15: ...electric codes Electrical connections should only be performed by a qualified licensed electrician main power must be off when connecting to main electrical power supply or performing service The blower when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI Z 223 1 NFPA 70 WARNING WARNING This fireplace ha...

Страница 16: ...Right Side Brick 1 20302359 71D3011 20302359 71D3011 4b Rear Brick 1 20302360 71D3010 20302365 71D3504 4c Left Side Brick 1 20302361 71D3012 20302361 71D3012 Accessories 1 Standard Brass Canopy 1 BRCU36 BRCU36 BRCU42 BRCU42 1 Wide Brass Canopy 1 BRC36 BRC36 BRC42 BRC42 5 Blower w Rheostat 1 BLOTMC BLOTMC BLOTMC BLOTMC 6 Brass Trim Curved Design 1 BRTKM36 BRTKM36 BRTKM42 BRTKM42 6 Pewter Trim Curve...

Страница 17: ...17 26D4750 MCUF Series Vent Free Firebox ...

Страница 18: ...26D4750 18 MCUF Series Vent Free Firebox ...

Страница 19: ...on instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation ...

Страница 20: ...Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com ...

Отзывы: