Control Board Diagnostics (ProX7 and ProX9)
312667H
27
Control Board Diagnostics (ProX7 and ProX9)
NOTE: Check for motor problems before replacing control board. A damaged motor may burn out a good control
card.
Check for a damaged control board or pressure control
switch as follows:
1.
Relieve Pressure, page 11.
2.
Unplug electrical cord.
3.
Remove four cover screws and front cover.
Remove motor enclosure.
4.
Remove yoke and guide rods.
5.
Remove gear.
6.
Remove pressure control harness from control
board. Using tip of small, flat blade screwdriver,
press tab on right side connector to release.
7.
Attach harness from a pressure control switch you
know is functioning correctly to control board.
NOTE: Pressure control switch does not have to be
installed in pump.
8.
Turn pressure control adjustment knob (C) +to max-
imum pressure setting.
9.
Plug electrical cord into 120VAC receptacle.
10. Turn power switch (B) ON.
•
If motor runs, replace pressure switch.
Pressure Control Switch Kit, page 28.
•
If motor does not run, replace control board
repeat test. Control Board Kit, page 28.
Control Board Diagnostics (X5 and X7)
NOTE: Check for motor problems before replacing control board. A damaged motor may burn out a good control
card.
1.
Unplug electrical cord and Relieve Pressure, page
11.
2.
Remove enclosure and check all control board
connectors for proper installation (see Wiring
Diagram, page 46).
3.
Check fuse on control board. If fuse is blown,
determine the cause before replacing control board
(see Advanced Troubleshooting, page 18).
Pump Diagnostics
When pump packings wear, paint begins to leak down
the outside of the pump. At the first sign of leakage,
replace the pump or additional damage to the drive train
could occur.
1.
X5 and X7: Replace pump using Pump Replace-
ment (Complete). See List of Kits, page 28.
ProX7 and ProX9: Replace pump using Pump
Repair kit. See List of Kits, page 28.
2.
If there is no paint leakage, see Advanced
Troubleshooting, page 18. Pump may not be
defective.
NOTICE
When repairing or cleaning the pump, never submerge
pump in water or allow fluid to enter pressure control.
Содержание 261815
Страница 83: ...Notes 312667H 51 Notes ...