9
CLEARANCES
NOTE: Clearances for the Insert models are shown on pages 21-24
CONVENTIONAL CLEARANCES
A…SIDEWALL
3 In. (75 mm)
B…BACK WALL
3 In. (75 mm)…… (VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”
CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).
C…CORNER WALL
3 In (75 mm)……. (VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”
CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).
D…VENT PIPE TO WALL
3 In (75 mm)…….. (MAINTAIN 3” INCH CLEARANCE FOR ALL INSTALLATIONS)
E…FLOOR PROTECTION FRONT 6 In (150 mm)
F…FLOOR PROTECTION SIDES
6 In (150 mm)
Floor protection must be 3/8” inch minimum thickness non-combustible material or equivalent extending beneath heater and to
the front/side/rear as indicated.
CHIMNEY AND CONNECTOR: 3” LISTED PELLET VENT ONLY
NOTE: REGARDLESS OF STOVE CLEARANCE, VENT PIPE MUST ALWAYS HAVE A 3” INCH CLEARANCE.
ALCOVE CLEARANCES
MIN. ALCOVE WIDTH
27 In. (694 mm)
MIN. ALCOVE HEIGHT
47 In. (1194 mm)
MAX. ALCOVE DEPTH
36 In. (914 mm)
WARNING: THE MINIMUM CLEARANCES LISTED ABOVE ARE BASED ON 3” INCH PL LISTED PELLET
VENT PIPE. IF YOUR APPIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT. PLEASE
FOLLOW THE PIPE MANUFACTURERS INSTRUCTIONS AND LOCAL BUILDING CODES FOR THE
CLEARANCE TO COMBUSTIBLES REQUIRED FOR THE INSTALLATION OF THE VENT PIPE BEING USED.
Содержание WINACP
Страница 21: ...21 MAGNUM WIN INSERT INSTALLATION...
Страница 25: ...25...
Страница 26: ...26 Fireplace Insert Shroud Installation Diagram...
Страница 27: ...27 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...
Страница 41: ...41 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT DHC 3000 AC board...
Страница 42: ...42 DC MODEL DDC 3000 WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...