background image

© 

2010 Magnum Energy, Inc

.

FAULT 

(red)

 - 

Under normal operating conditions, the FAULT 

indicator will be off. If there is a fault condition, this indicator will 

blink differently for each speci

fi

 c fault to help troubleshoot the 

inverter. Monitor this indicator for at least 10 seconds, and count 

the number of blinks that occur every four seconds to determine 

the particular reason for the shutdown. Once you have determined 

and cleared the fault, the inverter can be turned on. To help clear 

the fault condition, refer to the Troubleshooting section in the MM 

Series or MM-AE Series owner’s manual. 

• Blinks On 1 time every 4 seconds – 

Low Battery Voltage; the 

battery voltage level has dropped below 10.0 VDC (LBCO default 

setting**). 

Your batteries need to be charged. This fault condition 

will automatically clear when the battery voltage 

 12.5 VD

C or 

the inverters begins charging (on models that have the internal 

battery charger).
• Blinks On 2 times every 4 seconds – 

High Battery Voltage; the 

battery voltage is above 15.5 VDC. Reduce or turn off the external 

charging source to bring the battery voltage down.

• Blinks On 3 times every 4 seconds – 

Over-temperature condition; 

the internal temperature of the in

verter has risen above acceptable 

limits. This is caused by loads too great for the inverter to operate 

continuously, or by a lack of ventilation to the inverter. When the 

unit has cooled, it will automatically reset and resume operation.

• Blinks On 4 times every 4 seconds – AC Overload; the inverter 

has turned off because the connected loads are larger than 

inverter’s output capacity, or there is a short on the output wiring. 

The inverter can be restarted after the AC loads are reduced, 

or the wiring short has been removed. To restart the inverter, 

momentarily press the 

ON/OFF button on the inverter or remote.

• Blinks On 5 times every 4 seconds – Internal Fault; the inverter 

has turned off because it has detected an internal problem. To 

clear this fault, the inverter will need to be reset by: 1. Press 

and hold the ON/OFF switch on the inverter for 15 seconds (the 

status LED must begin to rapidly 

fl

 ash) or, 2. Disconnect all DC 

power to the inverter for at least 15 seconds, and then reconnect. 

After resetting the inverter, momentarily press the inverters 

ON/OFF switch and verify the fault has cleared. If the internal 

fault remains, the inverter requires service at an authorized repair 

facility. 

MM-RC Remote Only

The MM-RC includes three additional charging LED indicators for 

information on the operation of the battery charger. Monitor the 

indicators (at least 10 seconds) to determine the charger status.

3.0 Operation

9

Содержание M-RC

Страница 1: ...Owner s Manual MM R and M RC Remote Controls ...

Страница 2: ... 2010 Magnum Energy Inc ...

Страница 3: ...833 fax 425 353 8390 web www magnumenergy com Product Safety Instructions Read and follow all instructions and safety information contained in this manual before installing or using this product All electrical work must be performed in accordance with local state and federal electrical codes This product is designed for indoor compartment installation It must not be exposed to rain snow moisture o...

Страница 4: ...s 6 Operation 7 ON OFF Switch 7 Monitoring the LED Indicators 8 MM R and MM RC Remotes 8 MM RC Remote Only 9 4 0 Warranty and Service Information 11 List of Figures Figure 1 MM R and MM RC Remote Controls 1 Figure 2 Communications Cable Connections 2 Figure 3 Flush Mounting 3 Figure 4 Surface Mounting 4 Figure 5 Remote Display Dimensions 5 Figure 6 Mounting Ring Dimensions 5 Figure 7 LED Indicator...

Страница 5: ...tch The unit comes with 25 cable This remote is for the MM612 model requires serial number L1 201 or higher MM RC Provides six LED indicators for inverter and charger sta tus and includes a remote ON OFF switch The unit comes with 25 cable This remote is for the MM1212 MM612AE MM1512AE and MM1524AE models Figure 1 MM R and MM RC Remote Controls M M R M M R C B U LK A B S O R B FA U LT FLO A T A C ...

Страница 6: ...n the cable route from the remote to the inverter before you do any cutting or drilling to ensure there are no obstructions that can t be overcome Allow ample room to access the ON OFF switch view the LEDs for the inverter s operational status and for any troubleshooting Connecting the Communications Cable The communications cable is a 25 4 conductor cable wired like a normal telephone type cable ...

Страница 7: ...ns DO NOT cut the opening too big to ensure there are no openings around the display and that there is enough material for the screws to secure the display Remove any wall insulation if applicable that may contact the back of the remote 2 Route the communications cable from the inverter up into the opening in the wall 3 Connect the communications cable to the RJ11 jack at the rear of the remote co...

Страница 8: ...break the appropriate tab on the mounting ring 4 Pull the cable through the mounting ring and place the ring side with the removed tab over the communication cable against the wall 5 Position the mounting ring over the drilled holes and screw the mounting ring to the wall 6 Connect the communications cable routed through the mounting ring opening to the RJ11 connector on the rear of the remote dis...

Страница 9: ... 2010 Magnum Energy Inc Figure 5 Remote Display Dimensions Figure 6 Mounting Ring Dimensions 2 0 Installation 5 BULK ABSORB FLOAT INVERT AC IN FAULT ON OFF Side Front Side Front ...

Страница 10: ...wner s Manual to help clear the fault condition Factory Default Settings Your MM MM AE Series inverter has many functions that have changeable settings These settings are preset and loaded by the inverter when turned on However if the MM remote control is con nected to the inverter the settings from the remote override any default settings in the inverter The settings in the remote are saved in th...

Страница 11: ...er feature this switch can also be used to disable the charger Charger Standby so that all the incoming power can be used exclusively for the AC loads To turn the charger off press and hold the ON OFF switch for three seconds you must be in the Charge Mode When this happens the charging indicators BULK ABSORB and FLOAT will go off To turn the charger back on press and hold the ON OFF switch for th...

Страница 12: ...ergy from the battery to supply AC power to the loads connected to the inverter and AC IN LED indicator is On solid The inverter is in Standby The external AC power utility or generator connected to the inverter s input is passing through the inverter to power the AC loads The inverter will automatically turn on to power the AC loads if the external AC power is lost or disconnected Blinks On once ...

Страница 13: ...en above acceptable limits This is caused by loads too great for the inverter to operate continuously or by a lack of ventilation to the inverter When the unit has cooled it will automatically reset and resume operation Blinks On 4 times every 4 seconds AC Overload the inverter has turned off because the connected loads are larger than inverter s output capacity or there is a short on the output w...

Страница 14: ...uces charge rate to help stabilize the incoming AC voltage Off charger is not in Absorption Charge mode FLOAT green On solid Float Charging at the end of the absorb charging time the charger reduces the charge voltage to maintain the batteries at 13 4 VDC per Battery Type selection Blinks On 1 time every 4 seconds Charger Back off charger current is reduced This occurs if 1 The internal temperatur...

Страница 15: ... repair determined by the price paid by the original purchaser Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the product s original date of purchase by a dated bill of sale itemized receipt 5 The original purchaser shall return the product prepaid to Magnum Energy in Everett WA After the completion of service u...

Страница 16: ... 2010 Magnum Energy Inc Magnum Energy Inc 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www magnumenergy com PN 64 00012 Rev A ...

Отзывы: