4
1. Installation
1.2 Oven start-up and testing
Before commissioning the oven, scrupulously carry out the necessary checks to ensure the compliance of the
systems and installation of the appliance with the legal Standards and technical and safety indications in this
manual.
The following points must also be satisfied:
•
The ambient temperature of the place of installation of the oven must be higher than +4° C.
•
The cooking compartment must be empty.
•
All packaging must be fully removed, including the protective film applied on the oven walls.
•
The air vents and louvers must be open and not obstructed.
•
The eventually dismantled oven pieces must be, for installation purposes, re-mounted.
•
The main electric switch must be closed and the water and gas shut-off cocks upstream of the appliance must
be open.
Testing
The oven test is carried out by completing a sample cooking cycle enabling to check the correct functioning
of the appliance and the absence of anomalies or problems.
Switch on the oven via the main switch T1.
Set a cooking cycle with temperature at 150°C, time at 10 min. and humidity at 5%/min.
Press the T16 “Start/Stop” key”.
Scrupulously check the following list:
•
The lights inside the cooking compartment switch-on by pressing the appropriate key and, after 45 seconds,
unless switched off by pressing the key again, automatically switch-off.
•
The oven stops if the door is opened and starts working again when the door is closed.
•
The adjustment thermostat of the temperature inside the cooking compartment intervenes upon reaching of
the set temperature and the heating element(s) is/are temporarily switched off;
•
The fan(s) motor performs automatic inversion of the rotary direction; inversion happens every 3 minutes.
•
In ovens with two fans in cooking compartment, the motors have the same rotary direction.
•
Verify the leaking of water towards the fan of the humidity input tube in cooking compartment.
•
Once cooking cycle is completed, the oven emits a sound warning signal that lasts about 15 seconds.
IMPORTANT
In case of blockage of the procedures during the setting of the cooking phases, or to solve any other blockages
of the control panel, press, even more than once, the T15 key.