Tuffy Liquid Level Control with Pneumatic Switch

2.6

Parts

2.6.1 Physical

Pneumatic switch models

3.75 (95)

Float

minimum

clearance

2" NPT

2.50 (64) Dia.

.75

(19)

C

L

3.00 (76) max.
Nozzle length

7.96 (202) [Sp. Gr. 0.6 min.]

Float size = 2.00 (51) Dia. x 4.57 (116) long

8.91 (226) [Sp. Gr. 0.4 min.]

Float size = 2.00 (51) Dia. x 5.12 (130) long

Switch actuates
Rising level

Falling level
Switch actuates

12.94 (329) [Sp. Gr. 0.4 Min]

12.00 (304) [Sp.Gr. 0.6 Min]

1/4" NPT

inlet (A)

1/4" NPT
outlet (C)

1/4" NPT

inlet (B)

Pressure:

0.6 SG 1500 psig at +300° F (103 bar at +149° C)

0.4 SG 500 psig at +300° F (34 bar at +149° C)

Process Temperature:

-40° F to +300° F (-40° C to +149° C)

Ambient Temperature:

Max. +100° F (+38° C) with maximum process temperature

Pneumatic Switch Supply Pressure:

Vacuum to 200 psig (13.8 bar) maximum

Maximum Leakage Rate:

0.5 SCFH (0.015 SCMH @ 100 psig (6.9 bar))

Maximum Air Flow:

12.0 SCFH (0.34 SCMH @ 100 psig (6.9 bar))

Specific Gravity:

0.6 minimum or 0.4 minimum

Materials of Construction:

316/316L SS wetted components including NACE and ASME B31.3

Housing:

316 stainless steel

2.5

Specifications

2.5.1 Mechanical Specifications

0

3

9

6

0

0

0

1

0

BASIC MODEL NUMBER

0 3 9

Tuffy Float Switch

SWITCH ACTION

6

Pneumatic

HOUSING

0

316 Stainless steel with

1

/

4

" NPT airline connections

SPECIFIC GRAVITY AND PRESSURE RATINGS

0

0.60 minimum S.G., 1500 psi maximum pressure

4

0.40 minimum S.G., 500 psi maximum pressure

2.7

Model Numbers

Содержание Tuffy 039-6000-100

Страница 1: ...Side Mounted Float Level Switch Tuffy Liquid Level Controls with Pneumatic Switch Installation and Operating Manual...

Страница 2: ...any components WARNING Explosion hazard Do not connect or dis connect equipment unless power has been switched off or the area is known to be non hazardous Notice of Trademark Copyright and Limitation...

Страница 3: ...Ensure that the length and inside diameter of the mounting nozzle are sized correctly to allow for switch actuation at design levels Refer to Figure 1 2 Ensure that the mounting nozzle or coupling is...

Страница 4: ...ould be done in such a way as to minimize the action of dynamic forces on the float or displacer sensing element Good practice for reducing the likelihood of damage to the control is to equal ize pres...

Страница 5: ...he field of the switch mechanism magnet As a result the magnets repel causing the pivot arm and valve plunger to move so that air is allowed to pass from air inlet A to air outlet C As liquid level ri...

Страница 6: ...tory or your local representative 3 NEVER use in systems which have excess iron particles in the solution The magnet at the counterweight end of the float can attract the particles which could cause t...

Страница 7: ...40 F to 300 F 40 C to 149 C Ambient Temperature Max 100 F 38 C with maximum process temperature Pneumatic Switch Supply Pressure Vacuum to 200 psig 13 8 bar maximum Maximum Leakage Rate 0 5 SCFH 0 015...

Страница 8: ...e impaired Return Material Procedure So that we may efficiently process any materials that are returned it is essential that a Return Material Authorization RMA number be obtained from the fac tory pr...

Отзывы: