background image

Pneumatic switch mechanism and enclosure

Electronic switch mechanism & enclosure

3

Switch

Max. Process

Max. Supply

Material of

Pipe Size

Flow

Bleed Orifice

Code

Description

Temperature

Pressure

Construction

(NPT)

Rate

Diameter

(NEMA 1 Encl.)

3

4

" or 1"

A thru F

100 PSIG

Bronze

1

1

2

" or 2"

A thru D

0.63"

JDG

(7 Bar)

E and F

(1.6 mm)

JDE

Series J

400° F

S.S.

3

4

" thru 2"

A thru F

Bleed Type

(204° C)

3

4

" or 1"

A thru F

JEG

60 PSIG

Bronze

1

1

2

" or 2"

A thru D

0.94"

(4 Bar)

E and F

(2.4 mm)

JEE

S.S.

3

4

" thru 2"

A thru F

Series K

100 PSIG

Bronze

1

1

2

" or 2"

E and F

KOE

Non-Bleed

400° F

(7 Bar)

S.S.

3

4

" thru 2"

A thru F

Type

(204° C)

40 PSIG

3

4

" or 1"

A thru F

KOG

(3 Bar)

Bronze

1

1

2

" or 2"

A thru D

Max.

 

One

Body

Pipe

NEMA 4X/7/9

Switch

Process

Set Point

Material

Flow

Aluminum,

Aluminum,

Description

Temp.

Per

of

Size

Rate

Polymer

Cl

I

Div. 1

°F (°C)

Enclosure

Construction

(NPT)

Coated

Group B

3

4

" or 1"

A thru F

AKP

AKT

Bronze

1

1

2

" or 2"

A thru D

Series A

SPDT

E and F

AKQ

AKS

Mercury Switches

550

S.S.

3

4

" thru 2

A thru F

(228)

3

4

" or 1"

A thru F

ANP

ANT

Bronze

1

1

2

" or 2"

A thru D

DPDT

E and F

ANQ

ANS

S.S.

3

4

" thru 2

A thru F

3

4

" or 1"

A thru F

BKP

BKT

Bronze

1

1

2

"or 2"

A thru D

SPDT

E and F

BKQ

BKS

Series B

250

S.S.

3

4

" thru 2"

A thru F

Snap Switches

(121)

3

4

" or 1"

A thru F

BNP

BNT

Bronze

1

1

2

" or 2"

A thru D

DPDT

E and F

BNQ

BNS

S.S.

3

4

" thru 2"

A thru F

3

4

" or 1"

A thru F

CKP

CKT

Bronze

1

1

2

" or 2"

A thru D

SPDT

E and F

CKQ

CKS

Series C

450

S.S.

3

4

" thru 2

A thru F

Snap Switches

(232)

3

4

" or 1"

A thru F

CNP

CNT

Bronze

1

1

2

" or 2"

A thru D

DPDT

E and F

CNQ

CNS

S.S.

3

4

" thru 2

A thru F

Series D

250

SPDT

S.S.

3

4

" thru 2

A thru F

DKQ

DKS

Snap Switch for
High DC Current

(121)

DPDT

DNQ

DNS

3

4

" or 1"

A thru F

EKP

EKT

Bronze

1

1

2

" or 2"

A thru D

Series E

SPDT

E and F

EKQ

EKS

Vibration Resistant

550

S.S.

3

4

" thru 2

A thru F

Mercury Switches

(228)

3

4

" or 1"

A thru F

ENP

ENT

Bronze

1

1

2

" or 2"

A thru D

DPDT

E and F

ENQ

ENS

S.S.

3

4

" thru 2

A thru F

Series HS 5 Amp

 

550

SPDT

Bronze

3

4

" thru 2

A thru F

HMC

Hermetically Sealed
w/Wiring Leads

(228)

DPDT

S.S.

Series HS 5 Amp

 

550

SPDT

Bronze

3

4

" thru 2

A thru F

HM3

Hermetically Sealed
w/Terminal Block

(228)

DPDT

S.S.

Process temperature based on +100° F (+38° C) ambient.

Bronze models are rated to a maximum process temperature of +500° F (+260° C). Stainless steel models are limited
to the maximum temperature of the selected switch mechanism.

On condensing applications, temperature down-rated to +400° F (+204° C) process at +100° F (+38° C) ambient.

On models with bronze bodies with

3

4

" or 1" NPT pipe sizes, consult factory for HS switches.

 

HS switches are not available on models with stainless steel bodies.

Содержание F50

Страница 1: ...s action occurs Operating cycle On an increasing flow rate the flow disc moves the attrac tion sleeve up within the field of a switch magnet drawing it in tightly to the enclosing tube This causes the...

Страница 2: ...Agency approvals Model number construction F50 2 Basic part number materials of construction and pipe line size Actuating flow rate Switch mechanism and enclosure GENERAL INFORMATION 2 Model identific...

Страница 3: ...hru F Snap Switches 121 3 4 or 1 A thru F BNP BNT Bronze 11 2 or 2 A thru D DPDT E and F BNQ BNS S S 3 4 thru 2 A thru F 3 4 or 1 A thru F CKP CKT Bronze 11 2 or 2 A thru D SPDT E and F CKQ CKS Series...

Страница 4: ...ctions NOTE For proper performance a straight pipe run 12 pipe diameters upstream and three pipe diameters downstream of the switch is recommended Usually the first indication of improper operation is...

Страница 5: ...eumatic switches air or gas operat ing medium lines subjected to vibration may eventu ally crack or become loose at connections causing leakage Check lines and connections carefully and repair or repl...

Страница 6: ...29 NEMA 4X 7 9 151 108 NEMA 4X 7 9 5 93 4 29 10 75 4 60 Group B 151 108 273 116 NEMA 1 4 70 5 00 9 44 4 44 Pneumatic 119 127 240 113 NOTE 1 For NEMA 4X allow 8 00 203 overhead clearance for cover rem...

Страница 7: ...7127 001 32 7127 003 32 7127 002 32 7108 001 32 7109 001 32 7109 002 12 Lock Nut 10 2107 002 10 2107 003 10 2107 002 10 2107 003 13 Flow Disc Specify complete model number Switch Mechanism Series Refe...

Страница 8: ...gnetrol local representative or by contacting the factory Please supply the following information 1 Company Name 2 Description of Material 3 Serial Number 4 Reason for Return 5 Application Any unit th...

Отзывы: