4.8
Specifications
4.8.1 Functional
Measurement principle
Buoyancy – continuous displacement
utilizing a precision range spring
Input
Measured variable
Level, determined by LVDT core
movement affected by buoyancy force
changes on continuous displacer
Physical Range
Up to 120" (300 cm) based on
displacer length
Output (Digital ES II)
Type
Analog 4 to 20 mA direct or reverse
acting with HART® digital signal
Range
Analog 3.8 to 20.5 mA useable
Digital 0 to 100%
Loop Resistance (maximum)
545 Ohms @ 24 VDC
Fault
3.6 or 22 mA, selectable
Damping
Adjustable 0-60 seconds
Sampling Rate
Transmitter 15 times per second
Digital Meter 1.33 times per second
User Interface (Digital ES II)
Keypad
3 calibration buttons (up, down, enter)
Indication
3 LED’s on PCB for calibration and
functional checks
Digital communication
HART Version 5.x compatible
Power (Digital ES II)
Measured at instrument
12 to 36 VDC
terminals
Output (Analog EZ)
Type
Analog 4 to 20 mA direct
or reverse acting
Range
Analog 4 to 20 mA useable
Loop Resistance
(
maximum)
480 ohms @ 24 VDC
Fault
22 mA
User Interface (Analog EZ)
Potentiometers
Zero + Span controls
Action
Direct/Reverse switch
Power (Analog EZ)
Measured at instrument
12 to 36 VDC
terminals
120 VAC, 50/60 Hz
240 VAC, 50/60 Hz
Housing
Material
Polymer coated cast iron
Cable entry
1" NPT
39