Replacing the mixed bed resin: NF 2 plus, 6 plus

1. Close the ball valves, screw off 

the tank

2. Dispose of used resin 

with domestic waste, refill 

with new resin

3. Screw on the tank, re

-

set measuring computer, 

see instructions for use

Replacing the mixed bed resin: NF 12 plus, 25 plus

«0»

«0»

1. Close all valves, remove safety strainer on the 
drain tap

2. Connect a hose to the drain tap, with the other 
hose end in the supplied water permeable collec

-

tion bag

3. Connect the inlet to a drinking water tap with 
a hose

4. Open the inlet tap and the drain tap and flush 
out the resin until clear water comes out - the resin 
is then completly emptied.

5. Close the inlet tap and open the vent tap 
on the lid. Air can now get into the device and 
water in the filling station can flow out of the 
drain tap.

6. Used mixed bed resin can be disposed of 
with the normal household waste.

7. Close the drain tap, remove the hose and 
reinstall the safety strainer.

8. Refill with new resin.

9. Then vent the device again.

10. Put on the lid, connect the hoses and reset the 
measuring computer.

Содержание NF 2 plus

Страница 1: ...magnetic Demineralization Refill station NF plus Instructions for use magnetic einfach besser...

Страница 2: ...Unterm nkheim Tel 49 7944 94199 0 Fax 49 7944 94199 19 info magnetic online de www magnetic online de Managing Shareholder Michael Bader VAT ID No DE 255 018 730 Commercial Register No HRA 571362 Reg...

Страница 3: ...efill station NF plus Contents The function 4 Use with heating system filling hose 4 Permanent connection 5 Operating the meausuring computer 6 Replacing the mixed bed resin 7 Calculating the capacity...

Страница 4: ...e function The magnetic NF plus removes limescale and aggressive water constituents like sulphates nitrates and chlorides from the filling water The device works on the basis of a mixed bed resin ion...

Страница 5: ...n front of the filling station if the place of installation is subject to DIN EN 1717 Germany NF 2 plus 6 plus NF 12 plus NF 25 plus Untreated water backflow preventer Keep taps valves closed when not...

Страница 6: ...atic monitoring of the conductivity Set limit Press the S key to set the limit value for the conductivity in the display The increase step is 15 s cm A longer pressing of the S key resets the value ba...

Страница 7: ...ed water permeable collec tion bag 3 Connect the inlet to a drinking water tap with a hose 4 Open the inlet tap and the drain tap and flush out the resin until clear water comes out the resin is then...

Страница 8: ...tion removes all minerals 0 500 1000 1500 2000 2500 3000 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 CAPACITY IN LITER TOTAL HARDNESS IN DH CAPACITY REFILL STATION NF plus NF 2 plus NF 6 plus Capacity of...

Страница 9: ...g the batteries Remove the four front screws of the housing see illustration below and insert three batteries AAA alkaline into the battery holder The front part of the housing can be turned by 90 or...

Страница 10: ...er for flow rate total water flow quantity water quality and limit value checking Battery powered with automatic switch on function Suitable for permanent connection if the specific requirements and p...

Страница 11: ...magnetic einfach besser 11 Date Resin changed Liter total Signature Maintenance Installer Object Date of installation Serial number...

Страница 12: ...Am Richtbach 5 D 74547 Unterm nkheim Tel 49 7944 94199 0 Fax 49 7944 94199 19 info magnetic online de www magnetic online de Managing Shareholder Michael Bader VAT ID No DE 255 018 730 Commercial Reg...

Отзывы: