Adjusting the fixed end stops (gross adjustment)
The fixed end stops are used for gross adjustment. Tighten screws to 17 Nm.
Closed
1
a
b
c
d
e
f
2
3
Mag0059
8
0°
–120°
+120°
0°
Fig. 47: Gross adjustment
1 Fixed end stop for rotating direction to the left (Open from right)
2 Fixed end stop for rotating direction to the right (Open from left)
3 Blocking element in position "Closed" (locking element not yet mounted)
By positioning the two screws for the fixed end stops, you set the rotation
angle ranges for both rotating directions.
Marking in figure
Fixed end stop for rotating direction
to the left
Fixed end stop for rotating direction
to the right
a
0° … -10°
–
b
-10° … -55°
–
c
-55 … -100° (Factory setting)
+100° … +120°
d
-100° … -120°
+55 … +100° (Factory setting)
e
–
+10° … +55°
f
–
0° … +10°
Table 11:
Angle of rotation ranges depending on the set position