IMPULSE®•G+/VG+ Series 4 Analog Monitor Installation Manual
August 2011
1-18
Wire Gauges, Tightening Torques, and Crimp Terminals
Wire Gauges and Tightening Torques
Wire gauge and torque specifications are listed in Table 1.
Table 1: Wire Gauges and Tightening Torques
Crimp Terminals
Magnetek recommends using CRIMPFOX 6 by Phoenix Contact or equivalent crimp terminals with
the specifications listed in Table 2 for wiring to ensure proper connections.
NOTE:
Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
Table 2: Crimp Terminal Sizes
Terminal Functions
Table 3: Option Terminal Functions
<1> Set the functions and output levels for terminals V1 and V2 using drive parameters. See the drive Quick Start Guide or Instruction Manual
for directions on setting parameters.
Terminal
Size
Screw
Size
Tightening
Torque
N-m (in-lb)
Bare Cable
Crimp Terminals
Wire Type
Applicable
Gauges mm
2
Recomm.
Gauge mm
2
Applicable
Gauges mm
2
Recomm.
Gauge mm
2
V1, V2,
AC, FE
M2
0.22 to 0.25
(1.95 to 2.21)
Stranded wire:
0.25 to 1.0
(24 to 17 AWG)
Solid wire:
0.25 to 1.5
(24 to 16 AWG)
0.75
(18 AWG)
0.25 to 0.5
(24 to 20 AWG)
0.5
(20 AWG)
Shielded
twisted
pair, etc.
Wire Gauge
mm
2
Phoenix
Contact
Model
L
mm (in)
d1
mm (in)
d2
mm (in)
0.25 (24 AWG)
AI 0.25 - 6YE
10.5 (13/32)
0.8 (1/32)
2 (5/64)
0.34 (22 AWG)
AI 0.34 - 6TQ
10.5 (13/32)
0.8 (1/32)
2 (5/64)
0.5 (20 AWG)
AI 0.5 - 6WH
12 (15/32)
1.1 (3/64)
2.5 (3/32)
Terminal
Function
Signal Level
Description
V1
Analog voltage output 1
-10 to 10 V
•
Analog voltage output for an external
monitoring device <1>
Output resolution 11-bit plus sign (1/
2048)
•
Max. load current 3 mA
V2
Analog voltage output 2
AC
Common
0 V
Common for analog voltage output
FE
Ground
–
Used for grounding shielded lines