Room Availability Hallway Sign, Ceiling Mount

DO

 Mount the Assembly

The Crestron

®

 SSC room availability hallway sign installs into a conventional drywall or dropped tile 

ceiling. After installation, the SSC protrudes 5.18 in (132 mm) below the ceiling surface. 

To mount the SSC assembly into the ceiling:

NOTE:

 

Confirm that there are no fixtures, air ducts, joists, or other possible obstructions in the 

mounting location that may impede installation. Use a stud finder tool to help locate joists.

1.  After checking for obstructions, trace an outline of the mounting hole directly onto the 

drywall ceiling or dropped ceiling tile with the included 2 x 10.4 in (51 x 264 mm) template.

2.  Cut around the outline using an appropriate drywall saw to create the mounting hole.

NOTE:

 

The minimum mounting depth is 1.5 in (39 mm) for use with USB, while the 

minimum mounting depth is 2.5 in (64 mm) for use with a Cresnet

®

 network connection. For 

more information, refer to the product’s table of specifications on the Crestron website.

3.  Make all necessary cable connections to the assembly as described in the “DO Connect 

the Device” section below.

NOTE:

 

Observe all local building codes when running cables through the ceiling from the 

power source to the installation location.

4.  Insert the assembly, top side first, into the mounting hole until the bottom lip of the 

assembly engages the bottom of the ceiling.

5.  While holding the assembly in position, carefully tighten the four screws attached to the 

bottom of the assembly until the swiveling dogs attached to the screws are secured in 
place against the ceiling. Do overtighten the screws.

CAUTION:

 

Set the screwdriver torque to its lowest possible setting to avoid stripping the 

swiveling dogs and damaging the ceiling. If removing the assembly from the ceiling, ensure 
that the screwdriver rotation is set correctly before untightening the screws.

DO

 Connect the Device

The SSC may be powered and controlled by a Crestron TSS-7, TSS-10, TSW-760, or TSW-1060  
touch screen via USB, or by a Crestron control system or DMPS3 device via Cresnet. Both 
connection methods are described below.

NOTE:

 

The included USB cable is plenum rated for ceiling installations. If the installation requires 

Cresnet cables, use plenum rated Cresnet cables. 

 

USB:

 Use the included USB cable to connect the SSC to the touch screen. Connect the 

cable’s USB A connector to the touch screen and the micro USB connector to the SSC 
assembly. Out-of-the-box functionality is established via the touch screen room scheduling 
application, with no programming required. 

NOTE:

 

The TSS-7 and TSW-760 may use either PoE (Power over Ethernet) or PoE+ to 

supply power to the SSC over USB , but the TSS-10 and TSW-1060 must use only PoE+ to 
supply power to the SSC.

DO

 Check the Box

QTY

ITEM

PART NUM.

1

Bezel, Ceiling Sign

4526150

1

Cable, USB 2.0, A - Micro B, 15 ft (4.57 m), Plenum Rated

2049072

1

Connector, 4-Pin

2003576

1

Template, Cutout

4526484

 

Cresnet:

 Use any standard, plenum rated Cresnet cable and the included 4-pin terminal 

block to connect the SSC to a Crestron control system or DMPS3 device. The SSC is 
powered and controlled over Cresnet via programming in SIMPL Windows or  
Crestron Studio

®

 software.

NOTE:

 

The 

CNET ID

 button on the bottom of the assembly is used to identify the device on the 

network using the Network Tree Device View in Crestron Toolbox™ software. For more information, 
refer to the embedded Crestron Toolbox help file. 

The brightness of the SSC may be custom programmed as follows:

 

If the SSC is connected to a touch screen, brightness is controlled by sending a custom 
property to the touch screen in Crestron Fusion

®

 software. For more information, refer to 

the embedded Crestron Fusion help file.

 

If the SSC is connected to a control system, brightness is controlled via custom 
programming in SIMPL Windows or Crestron Studio. For more information, refer to the 
embedded SIMPL Windows or Crestron Studio help files.

DO

 Complete the Installation

1.  Align the acrylic face (included with the SSC kit or purchased separately) with the assembly 

so that the side of the acrylic face with the machined recesses is facing away from the side 
of the assembly with the CNET ID button. 

CNET (24 Y Z G):

To Cresnet

® 

network device

USB (micro):

To touch screen

Latch
release
tabs (2)

Acrylic
face

Assembly

CNET ID button

(on rear of assembly)

Machined recesses (2)